GB/T 14048.4-2010
Low-voltage switchgear and controlgear.Part 4-1:Contactors and motor-starters.Electromechanical contactors and motor-starters (Including motor protector) (English Version)

Standard No.
GB/T 14048.4-2010
Language
Chinese, Available in English version
Release Date
2010
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2021-04
Replace By
GB/T 14048.4-2020
Latest
GB/T 14048.4-2020
Replace
GB 14048.4-2003
Scope
This standard applies to the types of appliances specified in 1.1 and 1.2, the main contacts of which are used for connection to circuits with a rated voltage not exceeding 1000 V a.c. or 1500 V d.c. The starters and (or) contactors involved in this section are generally not used for breaking short-circuit currents. So proper short circuit protective devices form part of the equipment, but are not required for contactors or starters. This section applies to the following contactors and starters: contactors equipped with overload and (or) short-circuit protective devices; with separate short-circuit protective devices and (or) with separate short-circuit protective devices and their own overload protective devices Starter; After the contactor or starter is assembled with the short-circuit protective device according to the specified conditions, such as an integrated starter or a protective starter, it is regarded as an integral unit. In the integrated starter and protective starter, the circuit breaker or fuse combination as a short-circuit protection device should meet the requirements of GB 14048.2 and GB 14048.3 accordingly.

GB/T 14048.4-2010 Referenced Document

  • GB 14048.1-2006 Low-voltage switchgear and controlgear. Part 1: General rules
  • GB 14048.2-2008 Low-voltage switchgear and controlgear.Part 2: Circuitm-breakers
  • GB 14048.3-2008 Low-voltage switchgear and controlgear.Part 3:Switches,disconnectors,switch-disconnectors and fuse-combination units
  • GB 14048.5-2008 Low-voltage switchgear and controlgear.Part5-1: Control circuit devives and switching element.Electromechanical control circuit devices
  • GB 4824-2004 Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement
  • GB 755-2008 Rotating electrical machines.Rating and performance
  • GB/T 11021-2007 Electrical insulation.Thermal classification
  • GB/T 2421.1-2008 Environmental testing for electric and electronic products.General and guidance
  • GB/T 2423.1-2008 Environmental testing for electric and electronic products.Part 2:Test methods.Tests A:Cold
  • GB/T 2423.10-2008 Environmental testing for electric and electronic products.Part 2:Tests methods Test Fc:Vibration(sinusoidal)
  • GB/T 2423.18-2000 Environmental testing-Part 2: Tests-Test Kb:Salt mist,cyclic(sodium chloride solution)
  • GB/T 2423.2-2008 Environmental testing for electric and electronic products.Part 2:Test methods.Tests B:Dry heat
  • GB/T 2423.4-2008 Environmental testing for electrical and electronic products - Part 2: Test method Test Db alternating damp heat (12h + 12h cycle)
  • GB/T 2423.5-1995 Environmental testing for electric and electronic products. Part 2: Test methods. Test Ea and guidance: Shock
  • GB/T 2828.1-2003 Sampling procedures for inspection by attributes--Part 1: Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
  • GB/T 4798.1 Classification of environmental conditions—Classification of groups of environmental parameters and their severities Part1:—Storage*2019-08-30 Update
  • GB/T 4798.10 Environmental conditions existing in the application of electric and electronic products Guidance
  • GB/T 4798.2 Classification of environmental conditions—Classification of groups of environmental parameters and their severities—Part 2:Transportation and handling*2021-05-21 Update
  • GB/T 4798.3 Classification of environmental conditions—Classification of groups of environmental parameters and their severities—Part 3: Stationary use at weatherprotected locations*2023-05-23 Update
  • GB/T 4798.4 Classification of environmental conditions—Classification of groups of environmental parameters and their severities—Part 4: Stationary use at non-weatherprotected locations*2023-05-23 Update
  • GB/T 4798.5 Environmental conditions existing in the application of electric and electronic products.Section 5: Ground vehicle installations
  • GB/T 4798.6 Classification of environmental conditions.Classification of groups of environmental parameters and their severities.Ship environment*2012-11-05 Update
  • GB/T 4798.7 Environmental conditions existing in the application of electric and electronic products.Part 7: Portable and non-stationary use
  • GB/T 4798.9 Classification of environmental conditions.Classification of groups of environmental parameters and their severities.Microclimates inside products*2012-11-05 Update

GB/T 14048.4-2010 history

  • 2020 GB/T 14048.4-2020 Low-voltage switchgear and controlgear—Part 4-1: Contactors and motor-starters—Electromechanical contactors and motor-starters (Including motor protector)
  • 2010 GB 14048.4-2010 Low-voltage switchgear and controlgear.Part 4-1:Contactors and motor-starters.Electromechanical contactors and motor-starters (Including motor protector)
  • 2003 GB 14048.4-2003 Low-voltage switchgear and controlgear-Electromechanical contactors and motor-starters
  • 1993 GB 14048.4-1993 Low-voltage switchgear and controlgear. Low-voltage electromechanical contactors and motor starters

GB/T 14048.4-2010 Low-voltage switchgear and controlgear.Part 4-1:Contactors and motor-starters.Electromechanical contactors and motor-starters (Including motor protector) has been changed from GB 14048.4-2003 Low-voltage switchgear and controlgear-Electromechanical contactors and motor-starters.


GB/T 14048.4-2010 -All Parts

GB/T 14048.1-2023 Low voltage switchgear and controlgear Part 1: General principles GB/T 14048.10-2016 Low-voltage switchgear and controlgear—Part 5-2: Control circuit devices and switching elements—Proximity switches GB/T 14048.11-2016 Low-voltage switchgear and control gear.Part 6-1:Multiple function equipment.Transfer switching equipment GB/T 14048.12-2016 Low-voltage switchgear and controlgear Part 4-3: Contactors and motor starters for AC semiconductor controllers and contactors for non-motor loads GB/T 14048.13-2017 Low-voltage switchgear and controlgear—Part 5-3: Control circuit devices and switching elements—Requirements for proximity devices with defined behaviour under fault conditions (PDDB) GB/T 14048.14-2019 Low-voltage switchgear and controlgear—Part 5-5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function GB/T 14048.15-2006 Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) GB/T 14048.16-2016 Low-voltage switchgear and controlgear - Part 8: Built-in thermal protection (PTC) control units for rotating electrical machines GB/T 14048.17-2008 Low-voltage switchgear and controlgear.Part 5-4:Control circuit devices and switching elements.Method of assessing the performance of low-formance of low-energy contacts.Special tests GB/T 14048.18-2016 Low-voltage switchgear and controlgear.Part 7-3:Ancillary equipment.Safety requirements for fuse terminal blocks GB/T 14048.19-2013 Low-voltage switchgear and controlgear.Part 5-7: Control circuit devices and switching elements.Requirements for proximity devices with analogue output GB/T 14048.2-2020 Low-voltage switchgear and controlgear—Part 2: Circuit-breakers GB/T 14048.20-2013 Low-voltage switchgear and controlgear.Part 5-8:Control circuit devices and switching elements.Three-position enabling switches GB/T 14048.21-2013 Low-voltage switchgear and controlgear.Part 5-9: Control circuit devices and switching elements.Flow rate switches GB/T 14048.22-2022 Low-voltage switchgear and controlgear—Part 7-4: Ancillary equipment—PCB terminal blocks for copper conductors GB/T 14048.23-2022 Low-voltage switchgear and controlgear—Part 9-1: Active arc-fault mitigation systems—Arc quenching devices GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units GB/T 14048.4-2020 Low-voltage switchgear and controlgear—Part 4-1: Contactors and motor-starters—Electromechanical contactors and motor-starters (Including motor protector) GB/T 14048.5-2017 Low-voltage switchgear and controlgear—Part 5-1: Control circuit devices and switching element—Electromechanical control circuit devices GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) GB/T 14048.7-2016 Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors GB/T 14048.8-2016 Low-voltage switchgear and controlgear.Part 7-2:Ancillary equipment.Protective conductor terminal blocks for copper conductors GB/T 14048.9-2008 Low-voltage switchgear and controlgear - Section 6-2: Multiple function equipment control and protective switching devices (or equipment) (CPS)