This standard applies to switches, isolators, isolating switches and fuse combinations in power distribution circuits with a rated voltage not exceeding 1000 V AC or 1500 V DC. The manufacturer should specify the type, rating and characteristics of the fuse in accordance with the relevant standards of the combined fuse. This section does not apply to electrical appliances included in the scope of GB 14048.2, GB 14048.4 and GB 14048.5; however, if the shape and fuse combination appliances within the scope of this section are normally used for starting, accelerating and (or) stopping a single motor, The additional requirements specified in Appendix A shall be complied with. The requirements for three-pole switches for single-pole operation are included in Annex C. Auxiliary switches used in electrical appliances within the scope of this part shall meet the requirements of GB 14048.5. This standard does not include additional requirements for explosion-proof electrical appliances. The purpose of this standard is to specify: a) the characteristics of electrical appliances. b) Relevant conditions that electrical appliances should meet: 1) Operation and performance under normal use conditions; 2) Operation and performance under specified abnormal conditions (such as short-circuit conditions); 3) Dielectric properties. c) Tests to demonstrate compliance with these conditions and the methods used to carry out these tests. d) The data that should be marked on the electrical appliance or the data that the manufacturer (such as in the product catalogue) needs to provide.
GB 13539.3 Low-voltage fuses.Part 3:Supplementary requirements for fuses for use by unskilled persons(fuse mainly for household and similar applications).Examples of standardized systems of fuses A to F
GB 13539.4 Low-voltage fuses Supplementary requirements for fuse-links for the protection of semiconductor devices
GB 14048.1-2006 Low-voltage switchgear and controlgear. Part 1: General rules
GB 14048.2-2001 Low-voltage switchgear and controlgear Low-voltage circuit breakers
GB 14048.4-2003 Low-voltage switchgear and controlgear-Electromechanical contactors and motor-starters
GB 14048.5-2008 Low-voltage switchgear and controlgear.Part5-1: Control circuit devives and switching element.Electromechanical control circuit devices
GB 4824-2004 Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement
GB 9254-1998 Information technology equipment--Radio disturbance characteristics--Limits and methods of measurement
GB/T 17626.2-2006 Electromagnetic compatibility Testing and measurement techniques Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test
GB/T 17626.4-2008 Electromagnetic compatibility.Testing and measurement techniques.Electrical fast transient/burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility.Testing and measurement techniques.Surge immunity test
GB/T 17626.6-2008 Electromagnetic compatibility. Testing and measurement techniques. Immunity to conducted disturbances, induced by radio-frequency fields
GB/T 2900.18-2008 Electrotechnical terminology.Low voltage apparatus
GB/T 4728.7-2008 Graphical symbols for diagrams.Part7:Switchgear,controlgear and protective devices
GB/T 5465.2-2008 Graphical symbols for use on electrical equipment.Part 2: Graphical symbols
GB 14048.3-2008 history
2017GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units
2008GB 14048.3-2008 Low-voltage switchgear and controlgear.Part 3:Switches,disconnectors,switch-disconnectors and fuse-combination units
2002GB 14048.3-2002 Low-voltage switchgear and controlgear Part 3: Switches,disconnectors,switch-disconnectors and fuse-combination units
GB 14048.3-2008 Low-voltage switchgear and controlgear.Part 3:Switches,disconnectors,switch-disconnectors and fuse-combination units was changed to GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units.