GB/T 14048.10-2008
Low-voltage switchgear and controlgear.Part 5-2: Control circuit devices and switching element.Proximtiy switches (English Version)

Standard No.
GB/T 14048.10-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2017-03
Replace By
GB/T 14048.10-2016
Latest
GB/T 14048.10-2016
Replace
GB/T 14048.10-1999
Scope
This standard applies to inductive and capacitive proximity switches capable of detecting the presence or absence of metallic and/or non-metallic objects, ultrasonic proximity switches capable of detecting the presence or absence of objects reflecting sound, photoelectric proximity switches capable of detecting the presence or absence of objects Proximity switches and non-mechanical magnetic proximity switches that detect the presence or absence of magnetic objects. The above-mentioned proximity switches shall be fully enclosed and have semiconductor switching elements, which can be used to connect circuits with a rated voltage AC not exceeding 250V (50Hz or 60Hz), or DC not exceeding 300V. This section does not apply to proximity switches with analog output. This part is intended to explain the following contents of proximity switches: - definition; - classification; - characteristics; - product information; - normal use, installation and transport conditions; - structure and performance requirements; - rated characteristics Verification test.

GB/T 14048.10-2008 Referenced Document

  • GB 14048.1-2006 Low-voltage switchgear and controlgear. Part 1: General rules
  • GB 14048.5-2008 Low-voltage switchgear and controlgear.Part5-1: Control circuit devives and switching element.Electromechanical control circuit devices
  • GB 16895.1 Electrical installations of buildings. Part 1: Scope, object and fundamental principles
  • GB 16895.11 Electrical installations of buildings Part 4: Protection for safety,Chapter 44: Protection against overvoltages Section 442-Protection of low-voltage installations against temporary overvoltages and faults beween high-voltage systems and earth
  • GB 16895.12 Electrical installations of buildings Part 4: Protection for safety Chapter 44: Protection against overvoltages Section 443: Protection against overvoltages of atmospheric origin or due to switching
  • GB 16895.13 Low-voltage electrical installations.Part 7-701:Requirements for special installations or locations.Locations containing a bath or shower*2012-06-29 Update
  • GB 16895.14 Electrical installations of buildings.Part 7-703:Requirements for special installations or locations.Rooms and cabins containing sauna heaters*2010-11-10 Update
  • GB 16895.19 Electrical installations of buildings Part 7: Requirements for special installations or locations Section 702: Swimming pools and other basins
  • GB 16895.2 Electrical installations of buildings.Part 4-42:Protection for safety.Protection against thermal effects
  • GB 16895.20 Electrical installations of buildings Part 5: Selection and erection of electrical equipment Chapter 55: Other equipment Section 551: Low-voltage generating sets
  • GB 16895.21 Low-voltage electrical installations.Part 4-41:Protection for safety.Protection against electric shock*2011-12-30 Update
  • GB 16895.22 Electrical installations of buildings Part 5-53:Selection and erection of electrical equipment isolation,switching and control Section 534:Devices for protection against overvoltages
  • GB 16895.24 Electrical installations of buildings.Part 7-710:Requirements for special installations or locations.Medical locations
  • GB 16895.25 Electrical installations of buildings.Part 7-711:Requirements for special installations or locations.Exhibitions,shows and stands
  • GB 16895.26 Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses
  • GB 16895.27 Low-voltage electrical installations.Part 7-705:Requirements for special installations or locations.Agricultural and horticultural premises*2012-06-29 Update
  • GB 16895.28 Electrical installations of buildings.Part 7-714:Requirements for special installations or locations.External lighting installations
  • GB 16895.29 Electrical installations of buildings.Part 7-713:Requirements for special installations or locations.Furniture*2008-12-15 Update
  • GB 16895.3 Electrical installations of buildings--Part 5-54:Selection and erection of electrical equipment-Earthing arrangements,protective conductors and protective bonding conductors
  • GB 16895.30 Electrical installations of buildings.Part 7-715:Requirements for special installations or locations.Extra-low-voltae lighting installations*2008-12-15 Update
  • GB 16895.31 Electrical installations of buildings.Part 7-717:Requirements for special installations or locations.Mobile or transportable units*2008-12-15 Update
  • GB 16895.4 Electrical installations of buildings Part 4: Protection for safety Chapter 43: Protection against overcurrent
  • GB 16895.5 Low-voltage electrical installations.Part 4-43 Protection for safety.Protection against overcurrent*2012-06-29 Update
  • GB 16895.6 Electric installations of buildings-Part 5: Selection and erection of electrical equipment-Chapter 52: Wiring systems
  • GB 16895.7 Low-voltage electrial installatioins.Part 7-704:Requuirements for special installations or locations.Construction and demolition site installations*2009-04-21 Update
  • GB 16895.8 Low-voltage eletrical installations.Part 7-706:Requirements for special installations or locations.Conducting locations with restricted movement*2010-11-10 Update
  • GB 17625.2-2007 Electromagnetic compatibility (EMC).Limits.Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16A per phase and not subject to conditional connection
  • GB 4824-2004 Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement
  • GB 7947-2006 Basic and safety principles for man-machine interface, marking and identification. Identification of conductors by colours or numerals
  • GB/T 16514.2-2005 Electromechanical switches for use in electronic equipment Part 5:Sectional specification for pushbutton switches Section 1-Blank detail specification
  • GB/T 17045-2008 Protection against electric shock.Common aspects for installation and equipment
  • GB/T 17626.2-2006 Electromagnetic compatibility Testing and measurement techniques Electrostatic discharge immunity test
  • GB/T 2423.10-2008 Environmental testing for electric and electronic products.Part 2:Tests methods Test Fc:Vibration(sinusoidal)
  • GB/T 2423.22-2002 Environmental testing for electric and electronic products--Part 2: Test methods Test N: Change of temperature
  • GB/T 2423.4-2008 Environmental testing for electrical and electronic products - Part 2: Test method Test Db alternating damp heat (12h + 12h cycle)*2009-01-01 Update
  • GB/T 2423.5-1995 Environmental testing for electric and electronic products. Part 2: Test methods. Test Ea and guidance: Shock
  • GB/T 2900.18-2008 Electrotechnical terminology.Low voltage apparatus
  • GB/T 5465.2-2008 Graphical symbols for use on electrical equipment.Part 2: Graphical symbols

GB/T 14048.10-2008 history

  • 2016 GB/T 14048.10-2016 Low-voltage switchgear and controlgear—Part 5-2: Control circuit devices and switching elements—Proximity switches
  • 2008 GB/T 14048.10-2008 Low-voltage switchgear and controlgear.Part 5-2: Control circuit devices and switching element.Proximtiy switches
  • 1999 GB/T 14048.10-1999 Low-voltage switchgear and controlgear-Control circuit devices and switching element-Section 2: Proximity switches
Low-voltage switchgear and controlgear.Part 5-2: Control circuit devices and switching element.Proximtiy switches

GB/T 14048.10-2008 -All Parts

GB/T 14048.1-2023 Low voltage switchgear and controlgear Part 1: General principles GB/T 14048.10-2016 Low-voltage switchgear and controlgear—Part 5-2: Control circuit devices and switching elements—Proximity switches GB/T 14048.11-2016 Low-voltage switchgear and control gear.Part 6-1:Multiple function equipment.Transfer switching equipment GB/T 14048.12-2016 Low-voltage switchgear and controlgear Part 4-3: Contactors and motor starters for AC semiconductor controllers and contactors for non-motor loads GB/T 14048.13-2017 Low-voltage switchgear and controlgear—Part 5-3: Control circuit devices and switching elements—Requirements for proximity devices with defined behaviour under fault conditions (PDDB) GB/T 14048.14-2019 Low-voltage switchgear and controlgear—Part 5-5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function GB/T 14048.15-2006 Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) GB/T 14048.16-2016 Low-voltage switchgear and controlgear - Part 8: Built-in thermal protection (PTC) control units for rotating electrical machines GB/T 14048.17-2008 Low-voltage switchgear and controlgear.Part 5-4:Control circuit devices and switching elements.Method of assessing the performance of low-formance of low-energy contacts.Special tests GB/T 14048.18-2016 Low-voltage switchgear and controlgear.Part 7-3:Ancillary equipment.Safety requirements for fuse terminal blocks GB/T 14048.19-2013 Low-voltage switchgear and controlgear.Part 5-7: Control circuit devices and switching elements.Requirements for proximity devices with analogue output GB/T 14048.2-2020 Low-voltage switchgear and controlgear—Part 2: Circuit-breakers GB/T 14048.20-2013 Low-voltage switchgear and controlgear.Part 5-8:Control circuit devices and switching elements.Three-position enabling switches GB/T 14048.21-2013 Low-voltage switchgear and controlgear.Part 5-9: Control circuit devices and switching elements.Flow rate switches GB/T 14048.22-2022 Low-voltage switchgear and controlgear—Part 7-4: Ancillary equipment—PCB terminal blocks for copper conductors GB/T 14048.23-2022 Low-voltage switchgear and controlgear—Part 9-1: Active arc-fault mitigation systems—Arc quenching devices GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units GB/T 14048.4-2020 Low-voltage switchgear and controlgear—Part 4-1: Contactors and motor-starters—Electromechanical contactors and motor-starters (Including motor protector) GB/T 14048.5-2017 Low-voltage switchgear and controlgear—Part 5-1: Control circuit devices and switching element—Electromechanical control circuit devices GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) GB/T 14048.7-2016 Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors GB/T 14048.8-2016 Low-voltage switchgear and controlgear.Part 7-2:Ancillary equipment.Protective conductor terminal blocks for copper conductors GB/T 14048.9-2008 Low-voltage switchgear and controlgear - Section 6-2: Multiple function equipment control and protective switching devices (or equipment) (CPS)



Copyright ©2024 All Rights Reserved