GB 16895.26-2005
Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses (English Version)

Standard No.
GB 16895.26-2005
Language
Chinese, Available in English version
Release Date
2005
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 16895.26-2005
Scope
This standard specifies the minimum safety requirements for electrical installations for the design, installation and operation of movable, temporary or permanently installed electrical machinery and structures. To ensure that electrical machinery and structures are re-installed temporarily or permanently in playgrounds and circuses or any other location without loss of safety. The purpose of this standard is to provide electrical installation requirements for the components of entertainment facilities or their integral mechanical components. This section does not apply to electrical equipment used in machinery (see IEC 60204-1).

GB 16895.26-2005 history

  • 2005 GB 16895.26-2005 Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses
Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses

GB 16895.26-2005 -All Parts

GB 16895.1-1997 Electrical installations of buildings. Part 1: Scope, object and fundamental principles GB 16895.11-2001 Electrical installations of buildings Part 4: Protection for safety,Chapter 44: Protection against overvoltages Section 442-Protection of low-voltage installations against temporary overvoltages and faults beween high-voltage systems and earth GB 16895.12-2001 Electrical installations of buildings Part 4: Protection for safety Chapter 44: Protection against overvoltages Section 443: Protection against overvoltages of atmospheric origin or due to switching GB 16895.13-2012 Low-voltage electrical installations.Part 7-701:Requirements for special installations or locations.Locations containing a bath or shower GB 16895.14-2010 Electrical installations of buildings.Part 7-703:Requirements for special installations or locations.Rooms and cabins containing sauna heaters GB 16895.19-2002 Electrical installations of buildings Part 7: Requirements for special installations or locations Section 702: Swimming pools and other basins GB 16895.2-2005 Electrical installations of buildings.Part 4-42:Protection for safety.Protection against thermal effects GB 16895.20-2003 Electrical installations of buildings Part 5: Selection and erection of electrical equipment Chapter 55: Other equipment Section 551: Low-voltage generating sets GB 16895.21-2011 Low-voltage electrical installations.Part 4-41:Protection for safety.Protection against electric shock GB 16895.22-2004 Electrical installations of buildings Part 5-53:Selection and erection of electrical equipment isolation,switching and control Section 534:Devices for protection against overvoltages GB 16895.24-2005 Electrical installations of buildings.Part 7-710:Requirements for special installations or locations.Medical locations GB 16895.25-2005 Electrical installations of buildings.Part 7-711:Requirements for special installations or locations.Exhibitions,shows and stands GB 16895.26-2005 Electrical installations of buildings.Part 7-740:Requirements for special installations or locations.structures,amusement devices and booths at fairgrounds,amusement parks and circuses GB 16895.27-2012 Low-voltage electrical installations.Part 7-705:Requirements for special installations or locations.Agricultural and horticultural premises GB 16895.28-2008 Electrical installations of buildings.Part 7-714:Requirements for special installations or locations.External lighting installations GB 16895.29-2008 Electrical installations of buildings.Part 7-713:Requirements for special installations or locations.Furniture GB 16895.3-2004 Electrical installations of buildings--Part 5-54:Selection and erection of electrical equipment-Earthing arrangements,protective conductors and protective bonding conductors GB 16895.30-2008 Electrical installations of buildings.Part 7-715:Requirements for special installations or locations.Extra-low-voltae lighting installations GB 16895.31-2008 Electrical installations of buildings.Part 7-717:Requirements for special installations or locations.Mobile or transportable units GB 16895.4-2000 Electrical installations of buildings Part 4: Protection for safety Chapter 43: Protection against overcurrent GB 16895.5-2012 Low-voltage electrical installations.Part 4-43 Protection for safety.Protection against overcurrent GB 16895.6-2000 Electric installations of buildings-Part 5: Selection and erection of electrical equipment-Chapter 52: Wiring systems GB 16895.7-2009 Low-voltage electrial installatioins.Part 7-704:Requuirements for special installations or locations.Construction and demolition site installations GB 16895.8-2010 Low-voltage eletrical installations.Part 7-706:Requirements for special installations or locations.Conducting locations with restricted movement



Copyright ©2024 All Rights Reserved