GB/T 7165.4-2008
Equipment for continuous monitoring of radioactivity in gaseous effluents.Part 4:Specific requirements for radioactive iodine monitors (English Version)

Standard No.
GB/T 7165.4-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 7165.4-2008
Replace
GB/T 7165.4-1989
Scope
This part of GB/T 7165 applies to equipment for simultaneous, delayed or sequential measurement of all forms of radioactive iodine. When sampling the effluent for measurement, the iodine attached to the aerosol is typically collected by a pre-filter and analyzed separately in the laboratory to provide a complete measurement. The radioactive iodine monitor shall have the following functions: - measure the volume activity of iodine and iodine compounds in the gaseous effluent stream and the total activity of discharged radioactive iodine; When the threshold value is reached, an alarm signal is activated. These devices measure the activity of other radionuclides present in the gaseous effluent, including natural radionuclides. Screening for other nuclides is important when measuring low levels of radioactive iodine. In chimneys or ventilation ducts, this section considers both the use of activated carbon as a sampling medium for iodine and the direct measurement of iodine. The purpose of this section is to specify specific standard requirements for iodine monitors listed in Chapter 4, including technical characteristics and general test conditions, and to give examples of possible methods. GB/T 7165.1-2005 specifies the general requirements, technical characteristics, test methods, radiation characteristics, electrical characteristics, mechanical characteristics, safety characteristics and environmental characteristics of this type of equipment. Unless otherwise stated, these requirements apply to this section.

GB/T 7165.4-2008 Referenced Document

  • GB 9254 Limits and methods of measurement of radio disturbance for information technology equipment*2008-08-06 Update
  • GB/T 17626.1 Electromagnetic compatibility Testing and measurement techniques Overview of immunity test
  • GB/T 17626.10 Electromagnetic compatibility—Testing and measurement techniques—Damped oscillatory magnetic field immunity test*2017-12-29 Update
  • GB/T 17626.11 Electromagnetic Compatibility Testing and Measurement Techniques Part 11: Voltage Dips, Short Interruptions and Voltage Variation Immunity Tests for Equipment with Input Current Less than or Equal to 16 A per Phase*2023-05-23 Update
  • GB/T 17626.12 Electromagnetic Compatibility Testing and Measurement Techniques Part 12: Ringing Wave Immunity Test*2023-03-17 Update
  • GB/T 17626.13 Electromagnetic compatibility Testing and measurement techniques Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity test
  • GB/T 17626.14 Electromagnetic compatibility Testing and measurement techniques Voltage fluctuation immunity test
  • GB/T 17626.15 Electromagnetic compatibility.Testing and measurement techniques .Flickermeter.Functional and design specifications *2011-12-30 Update
  • GB/T 17626.16 Electromagnetic compatibility Testing and measurement techniques Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
  • GB/T 17626.17 Electromagnetic compatibility Testing and measurement techniques Ripple on d.c.input power port immunity test
  • GB/T 17626.18 Electromagnetic compatibility—Testing and measurement techniques—Damped oscillatory wave immunity test*2016-12-13 Update
  • GB/T 17626.19 Electromagnetic compatibility—Testing and measurement techniques—Part 19: Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c.*2022-12-30 Update
  • GB/T 17626.2 Electromagnetic compatibility.Testing and measurement techniques.Electrostatic discharge immunity test*2018-06-07 Update
  • GB/T 17626.20 Electromagnetic compatibility.Testing and measurement techniques.Emission and immunity testing in transverse electromagnetic (TEM) waveguide*2014-12-22 Update
  • GB/T 17626.21 Electromagnetic compatibility.Testing and measurement techniques.Reverberation chamber test methods*2014-12-22 Update
  • GB/T 17626.22 Electromagnetic compatibility (EMC)—Testing and measurement techniques—Radiated emissions and immunity measurements in fully anechoic rooms(FARs)*2017-12-29 Update
  • GB/T 17626.24 Electromagnetic compatibility.Testing and measurement techniques.Test methods for protective devices for HEMP conducted disturbance*2012-11-05 Update
  • GB/T 17626.27 Electromagnetic compatibility Testing and measurement techniques Unbalance immunity test
  • GB/T 17626.28 Electromagnetic compatibility Testing and measurement techniques Variation of power frequency, immunity test
  • GB/T 17626.29 Electromagnetic compatibility Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c.input power port immunity tests
  • GB/T 17626.3 Electromagnetic compatibility test and measurement technology Part 3: Radio frequency electromagnetic field radiation immunity test*2023-12-28 Update
  • GB/T 17626.30 Electromagnetic compatibility test and measurement technology Part 30: Power quality measurement methods*2023-12-28 Update
  • GB/T 17626.31 Electromagnetic compatibility—Testing and measurement techniques—Part 31:AC mains ports broadband conducted disturbance immunity test*2021-12-31 Update
  • GB/T 17626.34 Electromagnetic compatibility.Testing and measurement techniques.Voltage dips,short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase*2012-06-29 Update
  • GB/T 17626.4 Electromagnetic compatibility-Testing and measurement techniques-Electrical fast transient/burst immunity test*2018-06-07 Update
  • GB/T 17626.5 Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test*2019-06-04 Update
  • GB/T 17626.6 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances,induced by radio-frequency fields*2017-12-29 Update
  • GB/T 17626.7 Electromagnetic compatibility—Testing and measurement techniques—General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto*2017-07-12 Update
  • GB/T 17626.8 Electromagnetic compatibility Testing and measurement techniques Power frequency magnetic field immunity test
  • GB/T 17626.9 Electromagnetic compatibility. Testing and measurement techniques. Pulse magnetic field immunity test *2011-12-30 Update
  • GB/T 2423.5 Environmental testing—Part 2: Test methods—Test Ea and guidance: Shock*2019-05-10 Update
  • GB/T 7165.1-2005 Equipment for continuous monitoring of radioactivity in gaseous effluents Part1:General requirements

GB/T 7165.4-2008 history

  • 2008 GB/T 7165.4-2008 Equipment for continuous monitoring of radioactivity in gaseous effluents.Part 4:Specific requirements for radioactive iodine monitors
  • 1989 GB/T 7165.4-1989 Equipment for continuously monitoring radioactivity in gaseous effluents--Part 4: Specific requirements for iodine monitors
Equipment for continuous monitoring of radioactivity in gaseous effluents.Part 4:Specific requirements for radioactive iodine monitors

GB/T 7165.4-2008 -All Parts




Copyright ©2024 All Rights Reserved