GB/T 17626.5-2019
Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test (English Version)

Standard No.
GB/T 17626.5-2019
Language
Chinese, Available in English version
Release Date
2019
Published By
国家市场监督管理总局、中国国家标准化管理委员会
Latest
GB/T 17626.5-2019
Replace
GB/T 17626.5-2008
Scope
This part of GB/T17626 specifies the immunity requirements, test methods and recommended test level range for equipment to unipolar surge (shock) caused by switching and lightning transient overvoltage, and specifies the requirements for different environments and installation conditions. The next few test levels. The requirements set out in this standard apply to electrical and electronic equipment. The purpose of this section is to establish a common benchmark for evaluating the performance of electrical and electronic equipment when subjected to surges (shocks). This standard specifies a consistent test method to assess the immunity of equipment or systems to specified phenomena. Note: As stated in IEC Guide 107, this part is the basic standard for electromagnetic compatibility for use by product committees. IEC Guide 107 also stipulates that the product committee is responsible for determining whether to apply this immunity test standard and, if used, for determining the appropriate test level and performance criteria. The National Electromagnetic Compatibility Standardization Technical Committee and its sub-committees are willing to cooperate with product committees to evaluate the special immunity requirements of their products. This section specifies: --- the range of test levels; --- test equipment; --- test configuration; --- test procedures. The task of the laboratory test is to find out the reaction of the equipment to the surge (impulse) voltage generated by the switch or lightning under the specified working state. This section does not test the insulation capability of the EUT withstanding high voltage. This section does not consider the direct injection of lightning current for direct lightning strikes. 0.0050 unit PDFa factor u(xi )μs triangle 2. range 40 50 unit PDFa factor u(xi )μs·kHz rectangle 1.73 23. range 0.0075 unit PDFa factor u(xi )ci unit ui (y) unit V triangle 2. range 0.0050 1.4 50 Unit PDFa Factor u(xi )μs Trigonometric 2.

GB/T 17626.5-2019 history

  • 2019 GB/T 17626.5-2019 Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test
  • 2008 GB/T 17626.5-2008 Electromagnetic compatibility.Testing and measurement techniques.Surge immunity test
  • 1999 GB/T 17626.5-1999 Electromagnetic compatibility--Testing and measurement techniques--Surge immunity test
Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test

GB/T 17626.5-2019 -All Parts

GB/T 17626.1-2006 Electromagnetic compatibility Testing and measurement techniques Overview of immunity test GB/T 17626.10-2017 Electromagnetic compatibility—Testing and measurement techniques—Damped oscillatory magnetic field immunity test GB/T 17626.11-2023 Electromagnetic Compatibility Testing and Measurement Techniques Part 11: Voltage Dips, Short Interruptions and Voltage Variation Immunity Tests for Equipment with Input Current Less than or Equal to 16 A per Phase GB/T 17626.12-2023 Electromagnetic Compatibility Testing and Measurement Techniques Part 12: Ringing Wave Immunity Test GB/T 17626.13-2006 Electromagnetic compatibility Testing and measurement techniques Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity test GB/T 17626.14-2005 Electromagnetic compatibility Testing and measurement techniques Voltage fluctuation immunity test GB/T 17626.15-2011 Electromagnetic compatibility.Testing and measurement techniques .Flickermeter.Functional and design specifications GB/T 17626.16-2007 Electromagnetic compatibility Testing and measurement techniques Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz GB/T 17626.17-2005 Electromagnetic compatibility Testing and measurement techniques Ripple on d.c.input power port immunity test GB/T 17626.18-2016 Electromagnetic compatibility—Testing and measurement techniques—Damped oscillatory wave immunity test GB/T 17626.19-2022 Electromagnetic compatibility—Testing and measurement techniques—Part 19: Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. GB/T 17626.2-2018 Electromagnetic compatibility.Testing and measurement techniques.Electrostatic discharge immunity test GB/T 17626.20-2014 Electromagnetic compatibility.Testing and measurement techniques.Emission and immunity testing in transverse electromagnetic (TEM) waveguide GB/T 17626.21-2014 Electromagnetic compatibility.Testing and measurement techniques.Reverberation chamber test methods GB/T 17626.22-2017 Electromagnetic compatibility (EMC)—Testing and measurement techniques—Radiated emissions and immunity measurements in fully anechoic rooms(FARs) GB/T 17626.24-2012 Electromagnetic compatibility.Testing and measurement techniques.Test methods for protective devices for HEMP conducted disturbance GB/T 17626.27-2006 Electromagnetic compatibility Testing and measurement techniques Unbalance immunity test GB/T 17626.28-2006 Electromagnetic compatibility Testing and measurement techniques Variation of power frequency, immunity test GB/T 17626.29-2006 Electromagnetic compatibility Testing and measurement techniques Voltage dips, short interruptions and voltage variations on d.c.input power port immunity tests GB/T 17626.3-2023 Electromagnetic compatibility test and measurement technology Part 3: Radio frequency electromagnetic field radiation immunity test GB/T 17626.30-2023 Electromagnetic compatibility test and measurement technology Part 30: Power quality measurement methods GB/T 17626.31-2021 Electromagnetic compatibility—Testing and measurement techniques—Part 31:AC mains ports broadband conducted disturbance immunity test GB/T 17626.34-2012 Electromagnetic compatibility.Testing and measurement techniques.Voltage dips,short interruptions and voltage variations immunity tests for equipment with mains current more than 16A per phase GB/T 17626.39-2023 Electromagnetic compatibility test and measurement technology Part 39: Close range radiated field immunity test GB/T 17626.4-2018 Electromagnetic compatibility-Testing and measurement techniques-Electrical fast transient/burst immunity test GB/T 17626.5-2019 Electromagnetic compatibility—Testing and measurement techniques-Surge immunity test GB/T 17626.6-2017 Electromagnetic compatibility—Testing and measurement techniques—Immunity to conducted disturbances,induced by radio-frequency fields GB/T 17626.7-2017 Electromagnetic compatibility—Testing and measurement techniques—General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto GB/T 17626.8-2006 Electromagnetic compatibility Testing and measurement techniques Power frequency magnetic field immunity test



Copyright ©2024 All Rights Reserved