GB/T 17006.11-2015 Evaluation and routine testing in medical imaging departments.Part 2-6:Constancy tests.Imaging performance of computed tomography X-ray equipment (English Version)
This standard provides guidance for the stability test of X-ray computed tomography equipment (hereinafter referred to as CT scanning device). This standard applies to those components of CT scanning devices that affect image quality, patient dose and positioning. This standard: --Defines the basic parameters that describe the image quality, patient dose and positioning performance of CT scanning devices; see 4.5 for these parameters to be measured; --Describes the measurement methods of these basic parameters in detail; --Provides evaluation measurements The reference value and deviation standard of the parameters specified in the random documents used for data conformity. These methods rely on non-invasive measurements, using suitable test equipment, to ensure that the functional performance of the device meets established guidelines, or to enable early identification of changes in the characteristics of device components. The purpose is to verify compliance with specifications regarding image quality, patient dose and patient positioning. This standard does not deal with: - Mechanical and electrical safety aspects; - Mechanical, electrical and software performance aspects, unless they are elements of performing stability tests and directly affect image quality, patient dose and positioning.
GB/T 17006.11-2015 Referenced Document
GB 9706.18-2006 Medical electrical equipment. Part 2: Particular requirements for the safety of X-ray equipment for computed tomography
GB/T 19042.5-2006 Evaluation and routine testing in medical imaging department. Part 3-5: Acceptance tests. Imaging performances of computed tomography X-ray equipment
GB/T 17006.11-2015 history
2022GB/T 19042.5-2022 Evaluation and routine testing in medical imaging departments—Part 3-5:X-ray computed tomography equipment imaging performance acceptance test and constancy test
2015GB/T 17006.11-2015 Evaluation and routine testing in medical imaging departments.Part 2-6:Constancy tests.Imaging performance of computed tomography X-ray equipment
1997GB/T 17006-1997 Evaluation and routine testing in medical imaging departments--Part 2-6: Constancy tests--X-ray equipment for computed tomography
GB/T 17006.11-2015 Evaluation and routine testing in medical imaging departments.Part 2-6:Constancy tests.Imaging performance of computed tomography X-ray equipment has been changed from GB/T 17006-1997 Evaluation and routine testing in medical imaging departments--Part 2-6: Constancy tests--X-ray equipment for computed tomography.