GB/T 17006.6-2003
Evaluation and routine testing in medical imaging departments Part 2-4 Constancy tests-Hard copy cameras (English Version)

Standard No.
GB/T 17006.6-2003
Language
Chinese, Available in English version
Release Date
2003
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 17006.6-2003
Scope
This standard applies to hardcopy cameras that produce images on monochrome continuous light-sensitive materials (such as optical film and materials sensitive to infrared radiation), and includes cameras that use cathode ray tubes, laser beams, or thermoelectric printing systems, such as in Applied in the diagnostic imaging system: - digital radiography - digital subtraction - computed tomography imaging - magnetic resonance imaging - ultrasound imaging - nuclear medicine imaging This test method is based on the use of test patterns Base. This section does not apply to X-Y (analog) recording systems used in nuclear medicine. This Part is part of a series of dedicated publications (standards and technical reports), as described in GB/T 17006.1--2000 (see Chapter 2), which gives test methods for the stability of diagnostic imaging performance.

GB/T 17006.6-2003 history

  • 2003 GB/T 17006.6-2003 Evaluation and routine testing in medical imaging departments Part 2-4 Constancy tests-Hard copy cameras
Evaluation and routine testing in medical imaging departments Part 2-4 Constancy tests-Hard copy cameras

GB/T 17006.6-2003 -All Parts

GB/T 17006.1-2000 Evaluation and routine testing in medical imaging departments--Part 1: General aspects GB/T 17006.10-2003 Evaluation and routine testing in medical imaging departments--Part 2-11: Constancy tests--Equipment for general direct radiography GB/T 17006.11-2015 Evaluation and routine testing in medical imaging departments.Part 2-6:Constancy tests.Imaging performance of computed tomography X-ray equipment GB/T 17006.2-2000 Evaluation and routine testing in medical imaging departments--Part 2-1: Constancy tests--Film processors GB/T 17006.3-2000 Evaluation and routine testing in medical imaging departments--Part 2-2 Constancy tests-Radiographic cassettes and film changers-Film-screen contact and relative sensitivity of the screen-cassette assembly GB/T 17006.4-2000 Evaluation and routine testing in medical imaging departments-- Part 2-3: Constancy tests-Darkroom safelight conditions GB/T 17006.5-2000 Evaluation and routine testing in medical imaging departments--Part 2-5: Constancy tests-Image display devices GB/T 17006.6-2003 Evaluation and routine testing in medical imaging departments Part 2-4 Constancy tests-Hard copy cameras GB/T 17006.7-2003 Evaluation and routine testing in medical imaging departments--Part 2-7: Constancy tests--Equipment for intra-oral dental radiography excluding dental panoramic equipment GB/T 17006.8-2003 Evaluation and routine testing in medical imaging departments--Part 2-9: Constancy tests--Equipment for indirect radioscopy and indirect radiography GB/T 17006.9-2003 Evaluation and routine testing in medical imaging departments--Part 2-10: Constancy tests--X-ray equipment for mammography