GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)—Part 3: Cables for rated voltages of 35kV(Um=40.5kV) (English Version)
This part of GB/T12706 specifies the structure, dimensions and test requirements for fixedly installed extruded insulated power cables with a rated voltage of 35kV for use in distribution networks or industrial installations. This section applies to longitudinal water-blocking structural cables and their testing. This standard does not apply to cables with special installation and operating conditions, such as those used in overhead cables, in the mining industry, in nuclear power plants (in and near containments), and in cables used underwater or on ships.
GB/T 12706.3-2020 Referenced Document
GB/T 11017.2-2014 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110 kV(U<下标m>=126 kV).Part 2:Power cables
GB/T 12706.1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
GB/T 16927.1 High-voltage test techniques.Part 1:General definitions and test requirements
GB/T 17650.1 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 1:Determination of the halogen acid gas content*, 2021-04-30 Update
GB/T 17650.2 Test on gases evolved during combustion of materials from cables or optical fiber cables—Part 2: Determination of acidity (by pH measurement) and conductivity*, 2021-04-30 Update
GB/T 18380.11 Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus*, 2022-03-09 Update
GB/T 18380.12 Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame*, 2022-03-09 Update
GB/T 18380.13 Tests on electric and optical fibre cables under fire conditions—Part 13:Test for vertical flame propagation for a single insulated wire or cable—Procedure for determination of flaming droplets/particles*, 2022-03-09 Update
GB/T 18380.33 Tests on electric and optical fibre cables under fire conditions—Part 33:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category A*, 2022-04-15 Update
GB/T 18380.34 Tests on electric and optical fibre cables under fire conditions—Part 34:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category B*, 2022-04-15 Update
GB/T 18380.35 Tests on electric and optical fibre cables under fire conditions—Part 35:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category C*, 2022-03-09 Update
GB/T 18380.36 Tests on electric and optical fibre cables under fire conditions—Part 36:Test for vertical flame spread of vertically-mounted bunched wires or cables—Category D*, 2022-03-09 Update
GB/T 19666 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
GB/T 2951.11-2008 Common test method for insulating and sheathing materials of electric and optical cables.Part 11:Methods for general application.Measurement of thickness and overall dimensions.Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part 12:Methods for general application.Thermal ageing methods
GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part13:Methods for general application.Measurement for determining the density.Water absorption tests.Shrinkage test
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part 14:Methods for general application-Test at low temperature
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part21:Methods specific to elastomeric compounds.Ozone resistance,hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part31:Methods specific to PVC compounds.Pressure test at high temperature.Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part32:Methods specific to PVC compounds.Loss of mass test.Thermal stability test
GB/T 2951.41-2008 Common test method for insulating and sheathing materials of electric and optical cables.Part 41:Methods specific to polyethylene and polypropylene compounds.Resistance to environmental stress cracking.Measurement of the melt flow index.Carbon black and/o
GB/T 3048.10 Test methods for electrical properties of electric cables and wires.Part 10: Spark test of extruded protective sheaths
GB/T 3048.12 Test methods for electrical properties of electric cables and wires.Part 12: Partial discharge test
GB/T 3048.13 Test methods for electrical properties of electric cables and wires.Part 13: Impulse voltage test
GB/T 7113.2 Flexible insulating sleeving.Part 2:Methods of test
GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values
IEC 60229 Electric cables - Tests on extruded oversheaths with a special protective function
IEC 61034 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements*, 2024-04-21 Update
ISO 48 Rubber, vulcanized or thermoplastic - Determination of hardness (hardness between 10 IRHD and 100 IRHD)
JB/T 10696.6 Test methods for determining mechanical, physical and chemical properties of electric cables and wires Part 6: Test for abrasion of oversheaths
JB/T 8996 Guide to the selection of high-voltage cables
GB/T 12706.3-2020 history
2020GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
2008GB/T 12706.1-2008 Rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cables and accessories Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV) cables
2002GB/T 12706.1-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV) Part 1: Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV)
1991GB 12706.3-1991 Copper or aluminium conductor extruded plastic insulated power cables with rated voltages up to 35kV--Part 3: Cross-linked polyethylene insulated power cables