This standard specifies the type, basic parameters and dimensions, technical requirements, inspection rules and test methods of FTY series three-phase permanent magnet synchronous motors for textile use (frame size 80 to 355), as well as marking, packaging and warranty period requirements. This standard applies to FTY series three-phase permanent magnet synchronous motors (frame numbers 80 to 355) (hereinafter referred to as "motors") dedicated to various types of textile equipment such as cotton, wool, linen, silk and chemical fibers. This series of motors are self-starting permanent magnet synchronous motors. The motors specified in this standard have high overload capacity and fiber blocking ability, and are suitable for use in short fiber environments.
FZ/T 99010-2016 Referenced Document
FZ/T 90059-2009 Textile motor test method of damp heat in steady state
GB 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher.Measurement,evaluation and limits of vibration severity
GB 14711-2013 General requirements for safety of small and medium size rotating electrical machines
GB 1971-2006 Rotating electrical machines. Terminal markings and direction of rotation
GB 30253-2013 Minimum allowable values of energy efficiency and energy efficiency grades for permanent magnet synchronous motors
GB 755-2008 Rotating electrical machines.Rating and performance
GB/T 10069.1-2006 Measurement of airborne noise emitted by rotating electrical machines and the noise limits Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines
GB/T 191-2008 Packaging.Pictorial marking for handling of goods
GB/T 1993-1993 Cooling methods for rotating electrical machines
GB/T 22669-2008 Test procedures for three-phase permanent magnet synchronous machines
GB/T 22719.1-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines.Part 1:Test methods
GB/T 22719.2-2008 Interturn insulation of random-wound winding for AC low-voltage electrical machines.Part 2:Test limits
GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines. Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080
GB/T 4942.1-2006 Degrees of protection provided by the integral design of rotating electrical machined (IP code) - Classification
GB/T 997-2008 Rotating electrical machines.Classification of types of construction,mounting arrangements and terminal box position for(IM Code)
FZ/T 99010-2016 history
2016FZ/T 99010-2016 Specification for FTY series three-phase permanent magnet synchronous motorfor textile purpose(Frame size 80~355)
1970FZ/T 99010-1993 FTY type three-phase permanent magnet synchronous motor