This standard specifies the liquid chromatography-fluorescence detection method for aflatoxin B1, B2, G1, G2, M1, M2 content in milk and milk powder. This standard applies to the determination of aflatoxin B1, B2, G1, G2, M1, M2 content in milk and milk powder. The specific detection limit of this standard method: please refer to the specific content of the standard.
GB/T 23212-2008 Referenced Document
GB/T 6379.1 Accuracy(trueness and precision)of measurement methods and results Part 1:General principles and definitions
GB/T 6379.2 Accuracy(trueness and precision)of measurement methods and results-Part 2:Basic method for the determination of repeatability and reproducibility of a standard measurement method
GB/T 6682 Water for analytical laboratory use.Specification and test methods
GB/T 23212-2008 history
2017GB 5009.22-2016 Determination of Aflatoxin Group B and Group G in Food Safety National Standard Food
2008GB/T 23212-2008 Determination of aflatoxin B、B、G、G、M、M content in milk and milk powder.HPLC-fluorescence detection method
GB/T 23212-2008 Determination of aflatoxin B、B、G、G、M、M content in milk and milk powder.HPLC-fluorescence detection method was changed to GB 5009.22-2016 Determination of Aflatoxin Group B and Group G in Food Safety National Standard Food.
GB/T 23212-2008 Determination of aflatoxin B、B、G、G、M、M content in milk and milk powder.HPLC-fluorescence detection method was changed to GB 5009.24-2016 Determination of aflatoxin M group in foods with national food safety standards.