GB 19212.24-2005
Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites (English Version)

Standard No.
GB 19212.24-2005
Language
Chinese, Available in English version
Release Date
2005
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2021-07
Replace By
GB/T 19212.24-2020
Latest
GB/T 19212.24-2020
Scope
This chapter of GB/T 19212.1-2003 is replaced by the following content: This part specifies the safety requirements for various aspects of transformers (eg electrical, temperature and mechanical aspects). This section applies to stationary or mobile, single-phase or multi-phase, air-cooled (natural cooling or forced cooling), supporting or independent, isolation or safety isolation transformers for construction sites. Its rated power supply voltage does not exceed 1000V, and its rated frequency does not exceed 500Hz. The rated output shall not exceed: - 25kVA for single-phase transformers; - 40kVA for multi-phase transformers. The no-load output voltage and rated output voltage of isolation transformers for construction sites exceed 50V but do not exceed AC 250V. The no-load output voltage and rated output voltage of safety isolation transformers for construction sites shall not exceed AC 50V. When the transformer is installed in the low-voltage switchgear and control set for construction sites as specified in GB 7251.4-1009, the additional requirements in GB 7251.4-1998 also apply to the complete set of equipment. This section applies to dry-type transformers. Its windings can be hermetically sealed or unsealed. This standard applies to transformers containing electronic circuits. This standard does not apply to external circuits and components intended to be connected to transformer input terminals and output terminals or sockets.

GB 19212.24-2005 Referenced Document

  • GB 16895.7-2000 Electrical installations of buildings. Part 7: Requirements for special installations or locations. Section 704 -- Construction and demolition site installations
  • GB 7251.4-1998 Low-voltage switchgear and controlgear assemblies. Part 4: Particular requirements for assemblies for construction sites (ACS)
  • GB/T 2423.5-1995 Environmental testing for electric and electronic products. Part 2: Test methods. Test Ea and guidance: Shock

GB 19212.24-2005 history

  • 2020 GB/T 19212.24-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 24:Particular requirements and test for transformers and power supply units for construction sites
  • 2005 GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites
Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites

GB 19212.24-2005 -All Parts

GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB 19212.13-2005 Safety of power transformers,power supply units and similar devices.Part 13: Particular requirements for constant voltage transformers GB 19212.14-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 14:Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB 19212.16-2005 Safety of power transformers,power supply units and similar devices.Part 16: Particular requirements for isolating transformers for supply of medical locations GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB 19212.20-2008 Safety of power transformers,power supply units and similar.Part 20:Particular requirements for perturbation attenuation transformers GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites GB 19212.3-2012 Safety of power transformers,power supplies,reactors and similar products.Part 3:Particular requirements and tests for control transformers and power supplies incorporating control transformers GB 19212.4-2005 Safety of power transformers,power supply units and similar devices.Part 4: Particular requirements for ignition transformers for gas and oil burners GB 19212.5-2011 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100 V.Part 5:Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB 19212.6-2013 Safety of transformers,reactors,power supply units and combinations thereof.Part 6:Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units GB 19212.7-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 7:Particular requirements and rest for safety isolating transformers and power supply units incorporating safety isolating transformers GB 19212.8-2012 Safety of power transformers,power supplies,reactors and similar products.Part 8:Particular requirements and tests for transformers and power supplies for toys GB 19212.9-2007 Safety of power transformers, power supply units and similar devices Part 9: Particular requirements for bell and chime transformers