This document describes the detection methods of mass concentration, particle size, dispersion stability, superparamagnetism, magnetic recovery rate, target saturation binding capacity, target capture rate, capture specificity and capture rate stability of immunomagnetic materials. This document is applicable to the performance testing of composite materials with superparamagnetic properties and bioactive molecules such as antibodies or antigens immobilized on the surface within the particle size range of 50nm~100μm.
GB/T 40268-2021 Referenced Document
GB/T 13888 Method of measurement of the coercivity of magnetic materials in an open magnetic circuit
GB/T 15445.6 Representation of results of particle size analysis—Part 6: Descriptive and quantitative representation of particle shape and morphology