This International Standard specifies procedures for flash point tests, within the temperature range of –30 °C to 300 °C, for paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum, and related products. The procedures are used to determine whether a product will or will not flash at a specified temperature (flash no-flash Procedure A) or the flash point of a sample (Procedure B). When used in conjunction with the flash detector (A.1.6), this International Standard is also suitable to determine the flash point of fatty acid methyl esters (FAME).
ISO 3679:2015 Referenced Document
ASTM D6708-13 Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Material*, 2024-04-20 Update
ASTM D6751-15 Standard Specification for Biodiesel Fuel Blend Stock (B100) for Middle Distillate Fuels*, 2024-04-20 Update
ASTM E1137-97 Standard Specification for Industrial Platinum Resistance Thermometers
EN 14214:2012 Liquid petroleum products - Fatty acid methyl esters (FAME) for use in diesel engines and heating applications - Requirements and test methods [Superseded: CEN EN 14213]
IEC 60751:2008 Industrial platinium resistance thermometer and platinum temperature sensors
ISO 1513:2010 Paints and varnishes - Examination and preparation of test samples
ISO 1516:2002 Determination of flash/no flash - Closed cup equilibrium method
ISO 1523:2002 Determination of flash point - Closed cup equilibrium method
ISO 15528:2013 Paints, varnishes and raw materials for paints and varnishes.Sampling