GB 21904-2008
Discharge standard of water pollutants for pharmaceutical industry Chemical synthesis products category (English Version)

Standard No.
GB 21904-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 21904-2008
Scope
This standard specifies the discharge limits of water pollutants from chemical synthesis pharmaceutical enterprises or production facilities. This standard is applicable to the management of water pollutant discharge of existing chemical synthesis pharmaceutical enterprises or production facilities. This standard applies to the environmental impact assessment, environmental protection facility design, completion environmental protection acceptance and water pollutant discharge management of chemical synthesis pharmaceutical industry construction projects. This standard is also applicable to pharmaceutical intermediate factories (such as fine chemical factories) dedicated to pharmaceutical production. This standard is also applicable to the water pollution prevention and management of veterinary drug manufacturers with similar structures to chemically synthesized drugs. This standard applies to the discharge of pollutants permitted by law. The site selection of newly established pollution sources and the management of existing pollution sources in special protection areas shall be in accordance with the Law of the People's Republic of China on the Prevention and Control of Air Pollution, the Law of the People's Republic of China on the Prevention and Control of Water Pollution, the Law of the People's Republic of China on Marine Environmental Protection, and the The Law of the People's Republic of China on the Prevention and Control of Environmental Pollution by Solid Waste, the Law of the People's Republic of China on the Prevention and Control of Radioactive Pollution, and the Law of the People's Republic of China on Environmental Impact Assessment are implemented. The water pollutant discharge control requirements stipulated in this standard are applicable to the discharge behavior of enterprises to environmental water bodies. When enterprises discharge wastewater to urban drainage systems with sewage treatment plants, the toxic pollutants total cadmium, alkylmercury, hexavalent chromium, total arsenic, total lead, total nickel, and total mercury are discharged at the monitoring positions specified in this standard. The discharge control requirements of other pollutants shall be agreed upon by the enterprise and the urban sewage treatment plant according to its sewage treatment capacity or the relevant standards shall be implemented, and shall be reported to the local environmental protection authority for record; the urban sewage treatment plant shall ensure that the discharged pollutants meet the relevant discharge standards Require. When a construction project intends to discharge wastewater into the urban drainage system with a sewage treatment plant, the construction unit and the urban sewage treatment plant shall implement the provisions of the preceding paragraph.

GB 21904-2008 Referenced Document

  • GB/T 1.1 Directives for standardization—Part 1: Rules for the structure and drafting of standardizing documents*2020-03-31 Update
  • GB/T 1.2 Directives for standardization—Part 2:Drafting rules of standardizing documents based on ISO/IEC standardizing documents*2020-11-19 Update
  • GB/T 1.22 Directives for work of standardization Unit2:Methodology for the development of standards Part22:Rule of "reference to standards"
  • GB/T 1.4 Standardization Work Guidelines Chemical Analysis Method Standard Compilation Provisions
  • GB/T 1.6 Regulations on Compilation of Terminology Standards in Standardization Work Guidelines
  • GB/T 11889-1989 Water quality--Determination of aniline compounds--Spectrophotometric method with N-(1-naphthyl) ethylenediamine
  • GB/T 11893-1989 Water quality--Determination of total phosphorus--Ammonium molybdate spectrophotometric method
  • GB/T 11894-1989 Water quality--Determination of total nitrogen--Alkaline potassium persulfate digestion-UV spectro photometric method
  • GB/T 6920-1986 Water quality--Determination of pH value--Glass electrode method
  • GB/T 7467-1987 Water quality--Determination of chromium(6)--1.5 Diphenylcarbahydrazide spectrophotometric method
  • GB/T 7468-1987 Water quality--Determination of total mercury--Cold atomic absorption spectrophotometry
  • GB/T 7472-1987 Water quality--Determination of zinc--Spectrophotometric method with dithizone
  • GB/T 7474-1987 Water quality--Determination of copper--Sodium diethyldithiocarbamate spectrophotometric method
  • GB/T 7475-1987 Water quality--Determination of copper, zinc, lead and cadmium--Atomic absorption spectrometry
  • GB/T 7478-1987 Water quality--Determination of ammonium--Distillation and titration method
  • GB/T 7479-1987 Water quality--Determination of ammonium-Nessler's reagent colorimetric method
  • GB/T 7481-1987 Water quality--Determination of ammonium--Spectrophotometric method with salicylic acid
  • GB/T 7485-1987 Water quality--Determination of total arsenic--Silver diethyldithiocarbamate spectrophotometric method
  • GB/T 7486-1987 Water quality--Determination of cyanide--Part 1:Determination of total cyanide
  • GB/T 7488-1987 Water quality--Determination of biochemical oxygen demand after 5 days(BOD5)--Dilution and seeding method
  • GB/T 7490-1987 Water quality--Determination of volatile phenolic compounds--After distillation by means of 4-AAP spectrophotometric method

GB 21904-2008 history

  • 2008 GB 21904-2008 Discharge standard of water pollutants for pharmaceutical industry Chemical synthesis products category
Discharge standard of water pollutants for pharmaceutical industry Chemical synthesis products category