GB/T 6113.101-2008
Specification for radio disturbance and immunity measuring apparatus and methods.Part1-1:Radio disturbance and immunity measuring apparatus.Measuring apparatus (English Version)

Standard No.
GB/T 6113.101-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2016-11
Replace By
GB/T 6113.101-2016
Latest
GB/T 6113.101-2021
Replace
GB/T 6113.1-1995
Scope
This part of GB/T 6113 is the basic standard. This part specifies the performance and characteristics of measuring equipment used to measure radio disturbance voltage, disturbance current and disturbance field strength, and its frequency range is 9kHz~18GHz. In addition, special equipment for discontinuous disturbance measurements is also required. These requirements include wideband and narrowband measurements of radio disturbances. The types of measurement receivers involved include: a) quasi-peak measurement receivers; b) peak measurement receivers; c) mean value measurement receivers; d) root mean square (rms) measurement receivers. The requirements of this standard shall be met at all frequencies and all levels of radio disturbance voltages, currents, powers or field strengths within the range indicated by CISPR for the measuring equipment. Part 2 of GB/T 6113 specifies measurement methods, Part 3 gives more information about radio disturbances, and Part 4 contains content about uncertainty, statistics and limit modeling.

GB/T 6113.101-2008 Referenced Document

  • CISPR 14-1-2005 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
  • GB 4343.1-2003 Electromagnetic compatibility--Requirements for household appliances,electric tools and similar apparatus--Part 1: Emission
  • GB 4824-2004 Industrial,scientific and medical(ISM)radio-frequency equipment-Electromagnetic disturbance characteristics-Limits and methods of measurement
  • GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility
  • GB/Z 6113.3-2006 Specification for radio disturbance and immunity measuring apparatus and methods - Part3: CISPR technical report

GB/T 6113.101-2008 history

  • 2021 GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
  • 2016 GB/T 6113.101-2016 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
  • 2008 GB/T 6113.101-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part1-1:Radio disturbance and immunity measuring apparatus.Measuring apparatus
  • 1995 GB/T 6113.1-1995 Specifications for radio disturbance and immunity measuring apparatus

GB/T 6113.101-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part1-1:Radio disturbance and immunity measuring apparatus.Measuring apparatus has been changed from GB/T 6113.1-1995 Specifications for radio disturbance and immunity measuring apparatus.

Specification for radio disturbance and immunity measuring apparatus and methods.Part1-1:Radio disturbance and immunity measuring apparatus.Measuring apparatus

GB/T 6113.101-2008 -All Parts

GB/T 6113.1-1995 Specifications for radio disturbance and immunity measuring apparatus GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus GB/T 6113.102-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-2:Radio disturbance and immunity measuring apparatus—Coupling devices for conducted disturbance measurements GB/T 6113.103-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-3: Radio disturbance and immunity measuring apparatus—Ancillary equipment—Disturbances power GB/T 6113.104-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-4:Radio disturbance and immunity measuring apparatus—Antennas and test sites for radiated disturbance measurements GB/T 6113.105-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-5:Radio disturbance and immunity measuring apparatus—Antenna calibration sites and reference test sites for 5 MHz to 18 GHz GB/T 6113.106-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-6: Radio disturbance and immunity measuring apparatus—EMC antenna calibration GB/T 6113.2-1998 Methods of measurement of radio disturbance and immunity GB/T 6113.201-2018 Specification for radio disturbance and immunity measuring apparatus and methods-Part 2-1:Methods of measurement of disturbances and immunity-Conducted disturbance measurements GB/T 6113.202-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-2: Methods of measurement of disturbances and immunity—Measurement of disturbance power GB/T 6113.203-2020 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-3: Methods of measurement of disturbances and immunity—Radiated disturbance measurements GB/T 6113.204-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part 2-4:Methods of measurement of disturbances and immunity.Immunity measurements GB/T 6113.402-2022 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-2:Uncertainties,statistics and limit modelling—Measurement instrumentation uncertainty