GB/T 6113.101-2021
Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus (English Version)

Standard No.
GB/T 6113.101-2021
Language
Chinese, Available in English version
Release Date
2021
Published By
国家市场监督管理总局、中国国家标准化管理委员会
Latest
GB/T 6113.101-2021
Replace
GB/T 6113.101-2016
Scope
This document specifies the performance and characteristic requirements of measuring equipment for measuring radio disturbance, applicable to the frequency range of 9kHz~18GHz. This document also specifies requirements for dedicated equipment for intermittent disturbance measurements. Note: According to IEC guideline 107, CISPR16 1 1 is the basic electromagnetic compatibility (EMC) standard used by the product committee of IEC. As stated in IEC Guide 107, product committees have the responsibility to determine the applicability of EMC standards. CISPR and its subcommittees (corresponding to the domestic SAC/TC79 technical committee and its subcommittees) cooperate with these product committees in evaluating the value of specific tests for their specific products. The above product committees correspond to relevant domestic product technical committees. The requirements of this document apply to electromagnetic interference (EMI) receivers and spectrum analyzers. The term "measurement receiver" is used in this document to refer to both types of receivers, EMI receivers and spectrum analyzers (see also 3.7). Calibration requirements for measuring receivers are in accordance with Appendix K. Refer to CISPR16 2 for detailed usage guidelines for spectrum analyzers

GB/T 6113.101-2021 Referenced Document

  • GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility
  • GB/T 6113.202-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-2: Methods of measurement of disturbances and immunity—Measurement of disturbance power
  • GB/T 6113.203-2020 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-3: Methods of measurement of disturbances and immunity—Radiated disturbance measurements

GB/T 6113.101-2021 history

  • 2021 GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
  • 2016 GB/T 6113.101-2016 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
  • 2008 GB/T 6113.101-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part1-1:Radio disturbance and immunity measuring apparatus.Measuring apparatus
  • 1995 GB/T 6113.1-1995 Specifications for radio disturbance and immunity measuring apparatus
Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus

GB/T 6113.101-2021 -All Parts

GB/T 6113.1-1995 Specifications for radio disturbance and immunity measuring apparatus GB/T 6113.101-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus GB/T 6113.102-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-2:Radio disturbance and immunity measuring apparatus—Coupling devices for conducted disturbance measurements GB/T 6113.103-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-3: Radio disturbance and immunity measuring apparatus—Ancillary equipment—Disturbances power GB/T 6113.104-2021 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-4:Radio disturbance and immunity measuring apparatus—Antennas and test sites for radiated disturbance measurements GB/T 6113.105-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-5:Radio disturbance and immunity measuring apparatus—Antenna calibration sites and reference test sites for 5 MHz to 18 GHz GB/T 6113.106-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-6: Radio disturbance and immunity measuring apparatus—EMC antenna calibration GB/T 6113.2-1998 Methods of measurement of radio disturbance and immunity GB/T 6113.201-2018 Specification for radio disturbance and immunity measuring apparatus and methods-Part 2-1:Methods of measurement of disturbances and immunity-Conducted disturbance measurements GB/T 6113.202-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-2: Methods of measurement of disturbances and immunity—Measurement of disturbance power GB/T 6113.203-2020 Specification for radio disturbance and immunity measuring apparatus and methods—Part 2-3: Methods of measurement of disturbances and immunity—Radiated disturbance measurements GB/T 6113.204-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part 2-4:Methods of measurement of disturbances and immunity.Immunity measurements GB/T 6113.402-2022 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-2:Uncertainties,statistics and limit modelling—Measurement instrumentation uncertainty



Copyright ©2024 All Rights Reserved