Scope

4.1 Sampling at specified depth(s) within a liquid may be needed to confirm or rule out variations within a target population. This practice describes the design and operation of commercially available grab and discrete depth samplers for persons responsible for designing or implementing sampling programs, or both.

4.2 These sampling devices are used for sampling liquids in tanks, ponds, impoundments, and other open bodies of water. Some may be used from the edge or bank of the sampling site, whereas some can only be used from a platform, boat, or bridge over the sampling site. Some of the devices described are suitable for sampling slurries and sludges as well as aqueous and other liquids with few or no suspended solids.

4.3 Practice D5743 provides guidance for sampling drums, tanks, or similar containers.

4.4 This practice does not address general guidelines for planning waste sampling activities (Guide D4687), development of data quality objectives (Practice D5792), the design of monitoring systems and determination of the number of samples to collect (Practice D6311), in situ measurement of parameters of interest, data assessment and statistical interpretation of resultant data (Guide D6233), sample preservation, sampling and field quality assurance (Guide D5612), or the selection of sampling locations or obtaining a representative sample (Guide D6044).

1.1 This practice describes sampling devices and procedures for collecting samples of liquids or sludges, or both, whose upper surface can be accessed by the suitable device. These devices may be used to sample tanks that have an appropriately sized and located sampling port.

1.2 This practice describes and discusses the advantages and limitations of the following commonly used equipment, some of which can be used for both grab and discrete depth sampling: dipper, liquid grab sampler, swing jar sampler, Bacon Bomb, Kemmerer sampler, Discrete Level sampler, liquid profiler, peristaltic pump, and the Syringe sampler.

1.3 This practice provides instructions on the use of these samplers.

1.4 This practice does not address sampling devices for collecting ground water.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D6759-16 Referenced Document

  • ASTM D4687 Standard Guide for General Planning of Waste Sampling
  • ASTM D4840 Standard Guide for Sample Chain-of-Custody Procedures
  • ASTM D5088 Standard Practice for Decontamination of Field Equipment Used at Nonradioactive Waste Sites
  • ASTM D5283 Standard Practice for Generation of Environmental Data Related to Waste Management Activities: Quality Assurance and Quality Control Planning and Implementation
  • ASTM D5358 Standard Practice for Sampling With a Dipper or Pond Sampler
  • ASTM D5612 Standard Guide for Quality Planning and Field Implementation of a Water Quality Measurement Program
  • ASTM D5681 Standard Terminology for Waste and Waste Management
  • ASTM D5743 Standard Practice for Sampling Single or Multilayered Liquids, With or Without Solids, in Drums or Similar Containers
  • ASTM D5792 Standard Practice for Generation of Environmental Data Related to Waste Management Activities: Development of Data Quality Objectives
  • ASTM D5956 Standard Guide for Sampling Strategies for Heterogeneous Wastes
  • ASTM D6044 Standard Guide for Representative Sampling for Management of Waste and Contaminated Media
  • ASTM D6051 Standard Guide for Composite Sampling and Field Subsampling for Environmental Waste Management Activities
  • ASTM D6232 Standard Guide for Selection of Sampling Equipment for Waste and Contaminated Media Data Collection Activities
  • ASTM D6233 Standard Guide for Data Assessment for Environmental Waste Management Activities
  • ASTM D6311 Standard Guide for Generation of Environmental Data Related to Waste Management Activities: Selection and Optimization of Sampling Design
  • ASTM D6323 Standard Guide for Laboratory Subsampling of Media Related to Waste Management Activities
  • ASTM D6538 Standard Guide for Sampling Wastewater With Automatic Samplers
  • ASTM D6699 Standard Practice for Sampling Liquids Using Bailers

ASTM D6759-16 history

  • 2016 ASTM D6759-16 Standard Practice for Sampling Liquids Using Grab and Discrete Depth Samplers
  • 2009 ASTM D6759-09 Standard Practice for Sampling Liquids Using Grab and Discrete Depth Samplers
  • 2007 ASTM D6759-07 Standard Practice for Sampling Liquids Using Grab and Discrete Depth Samplers
  • 2002 ASTM D6759-02 Standard Practice for Sampling Liquids Using Grab and Discrete Depth Samplers
Standard Practice for  Sampling Liquids Using Grab and Discrete Depth Samplers



Copyright ©2024 All Rights Reserved