IEC 60947-4-3:2014
Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads

Standard No.
IEC 60947-4-3:2014
Release Date
2014
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 60947-4-3:2020
Latest
IEC 60947-4-3:2020
Replace
IEC 121A/2/FDIS:2014 IEC 60947-4-3:1999 IEC 60947-4-3 Corrigendum 1:2000 IEC 60947-4-3 AMD 1:2006 IEC 60947-4-3 AMD 2:2011 IEC 60947-4-3 Edition 1.1:2007 IEC 60947-4-3 Edition 1.2:2011
Scope
This part of IEC 60947 applies to a.c. semiconductor non-motor load controllers and contactors intended for performing electrical operations by changing the state of a.c. electric circuits between the ON-state and the OFF-state. Typical applications are classified by utilization categories given in Table 2. As controllers@ they may be used to reduce the amplitude of the r.m.s. a.c. voltage on the load terminals from that of the applied voltage ?C either continuously or for a specified period of time. The half-wave period of the a.c. wave form remains unchanged from that of the applied voltage. They may include a series mechanical switching device and are intended to be connected to circuits@ the rated voltage of which does not exceed 1 000 V a.c. This standard characterizes controllers and contactors for use with or without bypass switching devices. The semiconductor controllers and contactors dealt with in this standard are not normally intended to interrupt short-circuit currents. Therefore@ suitable short-circuit protection (see 8.2.5) should form part of the installation but not necessarily of the controller itself. In this context@ this standard gives requirements for semiconductor controllers and contactors associated with separate short-circuit protective devices. This standard does not apply to: ? operation of a.c. and d.c. motors; ? low-voltage a.c. semiconductor motor controllers and starters covered by IEC 60947-4-2; ? electronic a.c. power controllers covered by the IEC 60146 series; ? all-or-nothing solid-state relays. Contactors and control-circuit devices used in semiconductor controllers and contactors should comply with the requirements of their relevant product standard. Where mechanical switching devices are used@ they should meet the requirements of their own IEC product standard and the additional requirements of this standard. The object of this standard is to state a) the characteristics of semiconductor controllers and contactors and associated equipment; b) the conditions with which semiconductor controllers and contactors should comply with reference to: - their operation and behaviour; - their dielectric properties; - the degrees of protection provided by their enclosures@ where applicable; - their construction; c) the tests intended for confirming that these conditions have been met@ and the methods to be adopted for these tests; d) the information to be given with the equipment or in the manufacturer's literature.

IEC 60947-4-3:2014 Referenced Document

  • CISPR 11-2009 Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement
  • IEC 60269-1:2006 Low-voltage fuses - Part 1: General requirements
  • IEC 60410:1973 Sampling plans and procedures for inspection by attributes
  • IEC 60947-1:2007 Low-voltage switchgear and controlgear - Part 1: General rules
  • IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
  • IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measuring techniques - Electrostatic discharge immunity test
  • IEC 61000-4-3:2006 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

IEC 60947-4-3:2014 history

  • 2020 IEC 60947-4-3:2020 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - Semiconductor controllers and semiconductor contactors for non-motor loads
  • 2014 IEC 60947-4-3:2014 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
  • 1970 IEC 60947-4-3:1999/AMD2:2011 Amendment 2 - Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
  • 2011 IEC 60947-4-3:2011 Low-voltage switchgear and controlgear. Part 4-3: Contactors and motor-starters.AC semiconductor controllers and contactors for non-motor loads
  • 2007 IEC 60947-4-3:2007 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
  • 1970 IEC 60947-4-3:1999/AMD1:2006 Amendment 1 - Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
  • 1970 IEC 60947-4-3:1999/COR1:2000 Corrigendum 1 - Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads
  • 2000 IEC 60947-4-3/COR:2000 Low-Voltage Switchgear and Controlgear Part 4-3: Contactors and Motor-Starters - AC Semiconductor Controllers and Contactors for Non-Motor Loads (Edition 1.0)
  • 1999 IEC 60947-4-3:1999 Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - AC semiconductor controllers and contactors for non-motor loads



Copyright ©2024 All Rights Reserved