VDI 2463 Blatt 7-2014 Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS)
Owing to legal requirements such as the Federal Immission Control Act (BImSchG), the monitoring of suspended particulate matter with aerodynamic particle diameters < 10 ?m and < 2,5 ?m microns is of the utmost importance. The standard specifies requirements for a sampling device for active sampling of suspended particulate matter, dust components and selected gaseous compounds (e.g. polychlorinated dioxins) in ambient air and indoor air. It gives technical specifications, requirements for components and tolerances concerning volume flow (2,3 m3/h to 3,03/h) of the sampling device low-volume sampler (LVS).
VDI 2463 Blatt 7-2014 Referenced Document
DIN EN 12341:1999 Air quality - Determination of the PM10 fraction of suspended particulate matter - Reference method and field test procedure to demonstrate reference equivalence of measurement methods; German version EN 12341:1998
DIN EN 14902:2005 Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter; English version of DIN EN 14902
DIN EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air; German version EN 15549:2008
DIN ISO 16000-13:2010 Indoor air - Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Collection on sorbent-backed filters (ISO 16000-13:2008)
VDI 1000-2010 VDI Guideline Work - Principles and procedures
VDI 2267 Blatt 1-2012 Determination of suspended matter in ambient air - Measurement of the element concentration after sampling on filters - Determination of Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Sb, Se, Sn, Tl, V and Zn by graphite furnace atomic absorpt
VDI 2267 Blatt 12-2008 Determination of suspended matter in ambient air - Measurement of As, Ca, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb and Zn by energy dispersive X-ray fluorescense (ED XRF)
VDI 2267 Blatt 2-1983 Determination of suspended particulates in ambient air; measurement of lead by X-ray fluorescence
VDI 2449 Blatt 1-1995 Measurement methods test criteria - Determination of performance characteristics for the measurement of gaseous pollutants (immission)
VDI 2463 Blatt 8-2014 Particulate matter measurement - Determination of suspended particulate matter in ambient air and indoor air - Non-fractioning sampling system for low-volume samplers (LVS)
VDI 2464 Blatt 1-2009 Ambient air measurement - Indoor air measurement - Measurement of polychlorinated biphynyls (PCBs) - GC/MS method for PCB 28, 52, 101,138, 153, 180
VDI 2463 Blatt 7-2014 history
2014VDI 2463 Blatt 7-2014 Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS)
1982VDI 2463 Blatt 7-1982 Particulate matter measurement; measurement of mass concentration in ambient air; filter method; small filter device GS 050
1981VDI 2463 Blatt 7-1981 Determination of mass concentration of particulates in ambient air; filter method; small filter device GS 050/3