This standard specifies a method for the determination of silicon, manganese, phosphorus, chromium, nickel, molybdenum, copper, vanadium, aluminum, arsenic, tin and antimony in low alloy steel using laser ablation-inductively coupled plasma mass spectrometry. This standard is applicable to the determination of silicon, manganese, phosphorus, chromium, nickel, molybdenum, copper, vanadium, aluminum, arsenic, tin and antimony in low alloy steel, and can be used for in-situ and micro-area determination of bulk and chip samples. analyze. The measurement range is shown in Table 1.
YB/T 4308-2012 Referenced Document
GB/T 20066 Steel and iron.Sampling and preparation of samples for the determination of chemical composition
GB/T 6379.1 Accuracy(trueness and precision)of measurement methods and results Part 1:General principles and definitions
GB/T 6379.2 Accuracy(trueness and precision)of measurement methods and results-Part 2:Basic method for the determination of repeatability and reproducibility of a standard measurement method
YB/T 4308-2012 history
2012YB/T 4308-2012 Low alloy steel.Determination of multi-element contents.Laser ablation-inductively coupled plasma mass spectrometry (Routine method)