- Standard No.
- HJ 636-2012
- Language
- Chinese, Available in English version
- Release Date
- 2012
- Published By
- Professional Standard - Environmental Protection
- Latest
-
HJ 636-2012
- Replace
-
GB/T 11894-1989
- Scope
- This standard specifies the alkaline potassium persulfate digestion UV spectrophotometric method for the determination of total nitrogen in water. This standard is applicable to the determination of total nitrogen in surface water, groundwater, industrial wastewater and domestic sewage. When the sample volume is 10 ml, the detection limit of this method is 0.05 mg/L, and the determination range is 0.20~7.00 mg/L.
HJ 636-2012 Referenced Document
- HJ/T 164 Technical specifications for environmental monitoring of groundwater
- HJ/T 91 Technical Specifications Requirements for Monitoring of Surface Water and Waste Water
HJ 636-2012 history
- 2012 HJ 636-2012 Water quality.Determination of total nitrogen.Alkaline potassium persulfate digestion UV spectrophotometric method
HJ 636-2012 Water quality.Determination of total nitrogen.Alkaline potassium persulfate digestion UV spectrophotometric method has been changed from GB/T 11894-1989 Water quality--Determination of total nitrogen--Alkaline potassium persulfate digestion-UV spectro photometric method.