ASTM F1893-11
Guide for Measurement of Ionizing Dose-Rate Survivability and Burnout of Semiconductor Devices

Standard No.
ASTM F1893-11
Release Date
2011
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM F1893-18
Latest
ASTM F1893-18
Scope

The use of FXR or LINAC radiation sources for the determination of high dose-rate burnout in semiconductor devices is addressed in this guide. The goal of this guide is to provide a systematic approach to testing semiconductor devices for burnout or survivability.

The different types of failure modes that are possible are defined and discussed in this guide. Specifically, failure can be defined by a change in device parameters, or by a catastrophic failure of the device.

This guide can be used to determine if a device survives (that is, continues to operate and function within the specified performance parameters) when irradiated to a predetermined dose-rate level; or, the guide can be used to determine the dose-rate burnout failure level (that is, the minimum dose rate at which burnout failure occurs). However, since this latter test is destructive, the minimum dose-rate burnout failure level must be determined statistically.

1.1 This guide defines the detailed requirements for testing semiconductor devices for short-pulse high dose-rate ionization-induced survivability and burnout failure. The test facility shall be capable of providing the necessary dose rates to perform the measurements. Typically, large flash X-ray (FXR) machines operated in the photon mode, or FXR e-beam facilities are utilized because of their high dose-rate capabilities. Electron Linear Accelerators (LINACs) may be used if the dose rate is sufficient. Two modes of test are described: (1) A survivability test, and (2) A burnout failure level test.

1.2 The values stated in International System of Units (SI) are to be regarded as standard. No other units of measurement are included in this standard.

ASTM F1893-11 Referenced Document

  • ASTM E170 Standard Terminology Relating to Radiation Measurements and Dosimetry
  • ASTM E1894 Standard Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources
  • ASTM E668 Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
  • ASTM F526 Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

ASTM F1893-11 history

  • 2018 ASTM F1893-18 Guide for Measurement of Ionizing Dose-Rate Survivability and Burnout of Semiconductor Devices
  • 2011 ASTM F1893-11 Guide for Measurement of Ionizing Dose-Rate Survivability and Burnout of Semiconductor Devices
  • 1998 ASTM F1893-98(2003) Guide for Measurement of Ionizing Dose-Rate Burnout of Semiconductor Devices
  • 1998 ASTM F1893-98 Guide for Measurement of Ionizing Dose-Rate Burnout of Semiconductor Devices
Guide for Measurement of Ionizing Dose-Rate Survivability and Burnout of Semiconductor Devices