UL 60947-7-1-2004
Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors

Standard No.
UL 60947-7-1-2004
Release Date
2004
Published By
Underwriters Laboratories (UL)
Status
 2011-05
Replace By
UL 60947-7-1 (ND)-2004
Latest
UL 60947-7-1-2021
Scope
This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to connect round copper conductors, with or without special preparation, having a cross-section between 0,2 mm2 and 300 mm2 (AWG 24/600 kcmil), intended to be used in circuits of a rated voltage not exceeding 1000 V a.c. up to 1000 Hz or 1500 V d. NOTE: AWG is the abbreviation of "American Wire Gage" (Gage (US) = Gauge (UK)) kcmil = 1000 cmil; 1 cmil = 1 circular mil = surface of a circle having a diameter of 1 mil 1 mil = 1/1000 inch. This standard may be used as a guide for - terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.; - terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc.; - special types of terminal blocks, for example disconnect terminal blocks, etc. Where applicable in this standard, the term "clamping unit" has been used instead of the term "terminal". This is taken into account in case of reference to IEC 60947-1. 1.1 Addition: This standard applies to insulation displacement terminals. 1.1 Addition: AWG range expanded to include AWG 30 to 2,000 kcmil. 1.1 Addition: See Annex dva for Aluminum Requirements. 1.1 Addition: Voltage range expanded to include up to 1,500 Vac. Note: These requirements do not cover field installed power distribution blocks intended to distribute power in a building to separate units such as apartments, separate heaters, and air conditioning units. Power distribution blocks are investigated to Subject 1953, Outline of Investigation for Power Distribution Blocks.

UL 60947-7-1-2004 history

  • 2021 UL 60947-7-1-2021
  • 2017 UL 60947-7-1 (ND)-2017 National Differences For Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Fourth Edition)
  • 2017 UL 60947-7-1-2017 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Fourth Edition)
  • 2014 UL 60947-7-1 BULLETIN-2014 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (COMMENTS DUE: December 1@ 2014)
  • 2011 UL 60947-7-1 (ND)-2011 National Differences For UL 60947-7-1 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (Third Edition; Reprint with Revisions Through and Including October 14, 2011)
  • 2011 UL 60947-7-1-2011 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Third Edition; Reprint with revisions through and including October 14@ 2011)
  • 2009 UL 60947-7-1 BULLETIN-2009 UL Standard for Safety for Low-Voltage Switchgear and Controlgear Part 7-1: Ancillary Equipment - Terminal Blocks for Copper Conductors (COMMENTS DUE: October 12@ 2009)
  • 2008 UL 60947-7-1 BULLETIN-2008 UL Standard for Safety Low-Voltage Switchgear and Controlgear – Part 7-1: Ancillary Equipment – Terminal Blocks for Copper Conductors (COMMENTS DUE: September 10@ 2008)
  • 2004 UL 60947-7-1 BULLETIN-2004 UL Standard for Safety Low-Voltage Switchgear and Controlgear – Part 7-1: Ancillary Equipment – Terminal Blocks for Copper Conductors
  • 2004 UL 60947-7-1 (ND)-2004 National Differences For UL 60947-7-1 Standard for Low-Voltage Switchgear And Controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (Second Edition)
  • 2004 UL 60947-7-1-2004 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors



Copyright ©2024 All Rights Reserved