UL 60947-7-1 BULLETIN-2014
UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (COMMENTS DUE: December 1@ 2014)

Standard No.
UL 60947-7-1 BULLETIN-2014
Release Date
2014
Published By
Underwriters Laboratories (UL)
Status
 2017-02
Replace By
UL 60947-7-1-2017
Latest
UL 60947-7-1-2021
Scope
"This part of IEC 60947 specifies requirements for terminal blocks with screw-type or screw-less-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection between copper conductors. It applies to terminal blocks intended to connect round copper conductors@ with or without special preparation@ having a cross-section between 0@2 mm2 and 300 mm2 (AWG 24/600 kcmil)@ intended to be used in circuits of a rated voltage not exceeding 1 000 V a.c. up to 1 000 Hz or 1 500 V d. NOTE AWG is the abbreviation of ""American Wire Gage"" (Gage (US) = Gauge (UK)) kcmil = 1000 cmil; 1 cmil = 1 circular mil = surface of a circle having a diameter of 1 mil 1 mil = 1/1000 inch This standard may be used as a guide for ?C terminal blocks requiring the fixing of special devices to the conductors@ for example quick connect terminations or wrapped connections@ etc.; ?C terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation@ for example insulation displacement connections@ etc.; ?C special types of terminal blocks@ for example disconnect terminal blocks@ etc. Where applicable in this standard@ the term ""clamping unit"" has been used instead of the term ""terminal"". This is taken into account in case of reference to IEC 60947-1."

UL 60947-7-1 BULLETIN-2014 history

  • 2021 UL 60947-7-1-2021
  • 2017 UL 60947-7-1 (ND)-2017 National Differences For Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Fourth Edition)
  • 2017 UL 60947-7-1-2017 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Fourth Edition)
  • 2014 UL 60947-7-1 BULLETIN-2014 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (COMMENTS DUE: December 1@ 2014)
  • 2011 UL 60947-7-1 (ND)-2011 National Differences For UL 60947-7-1 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (Third Edition; Reprint with Revisions Through and Including October 14, 2011)
  • 2011 UL 60947-7-1-2011 UL Standard for Safety Low-voltage switchgear and controlgear – Part 7-1: Ancillary equipment – Terminal blocks for copper conductors (Third Edition; Reprint with revisions through and including October 14@ 2011)
  • 2009 UL 60947-7-1 BULLETIN-2009 UL Standard for Safety for Low-Voltage Switchgear and Controlgear Part 7-1: Ancillary Equipment - Terminal Blocks for Copper Conductors (COMMENTS DUE: October 12@ 2009)
  • 2008 UL 60947-7-1 BULLETIN-2008 UL Standard for Safety Low-Voltage Switchgear and Controlgear – Part 7-1: Ancillary Equipment – Terminal Blocks for Copper Conductors (COMMENTS DUE: September 10@ 2008)
  • 2004 UL 60947-7-1 BULLETIN-2004 UL Standard for Safety Low-Voltage Switchgear and Controlgear – Part 7-1: Ancillary Equipment – Terminal Blocks for Copper Conductors
  • 2004 UL 60947-7-1 (ND)-2004 National Differences For UL 60947-7-1 Standard for Low-Voltage Switchgear And Controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (Second Edition)
  • 2004 UL 60947-7-1-2004 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors



Copyright ©2024 All Rights Reserved