This standard specifies the silver diethyldithiocarbamate spectrophotometric method for the determination of arsenic and its compounds present in the form of particulate matter in air and exhaust gases. This standard is applicable to the determination of arsenic and its compounds existing in the form of particulate matter in air and exhaust gas. When the filter cartridge or filter membrane is prepared into a 50ml sample in this method, the detection limit is 0.35μg/50ml (calculated as As). For organized exhaust gas emissions, when 400L of gas is collected, the detection limit is 0.9 μg/m, and the lower limit of determination is 3.5 μg/m (both calculated as As). For air samples, when collecting 6m gas, the detection limit is 0.06μg/m, and the lower limit of determination is 0.24μg/m (both calculated as As).
HJ 540-2009 Referenced Document
GB/T 15432 Gravimetric Method for Determination of Total Suspended Particulate Matter in Ambient Air "Revision No. 1"*, 2018-08-13 Update
GB/T 16157 "Determination of Particulate Matter in Exhaust from Stationary Pollution Sources and Sampling Methods of Gaseous Pollutants" Amendment No. 1*, 2017-12-29 Update
GB/T 6682 Water for analytical laboratory use.Specification and test methods
HJ/T 194 Manual methods for ambient air quality monitoring
HJ/T 373 Technical specifications of quality assurance and quality control for monitoring of stationary pollution source (on trial)