GB/T 12706.2-2008
Power cables with extruded insulation and their accessories for rated voltages from 1kV(U=1.2kV>up to 35kV(U=40.5kV).Part 2:Cables for rated voltages from 6kV(U=7.2KV)up to 30kV(U=36kV) (English Version)

Standard No.
GB/T 12706.2-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2020-10
Replace By
GB/T 12706.2-2020
Latest
GB/T 12706.2-2020
Replace
GB/T 12706.2-2002
Scope
This part of GB/T 12706 specifies the requirements for distribution networks or industrial installations. Construction of extruded insulated power cables for fixed installations with rated voltages from 6 kV to 30 kV; dimensions and test requirements. When deciding on the cable application, it is recommended to consider the possible risk of radial water ingress. This standard covers so-called longitudinal water-blocking structural cables and their tests. This section does not cover cables for special installation and operating conditions, such as overhead cables, mining industry, nuclear power plants (in and near containment), and cables for underwater or ship use.

GB/T 12706.2-2008 Referenced Document

  • GB/T 11091-2005 Copper strips for cables
  • GB/T 156-2007 Standard voltages
  • GB/T 16927.1-1997 High-voltage test techniques. Part 1: General test requirements
  • GB/T 2951.11-2008 Common test method for insulating and sheathing materials of electric and optical cables.Part 11:Methods for general application.Measurement of thickness and overall dimensions.Tests for determining the mechanical properties
  • GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part 12:Methods for general application.Thermal ageing methods
  • GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part13:Methods for general application.Measurement for determining the density.Water absorption tests.Shrinkage test
  • GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part21:Methods specific to elastomeric compounds.Ozone resistance,hot set and mineral oil immersion tests
  • GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part31:Methods specific to PVC compounds.Pressure test at high temperature.Test for resistance to cracking
  • GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part32:Methods specific to PVC compounds.Loss of mass test.Thermal stability test
  • GB/T 2951.41 Common test method for insulating and sheathing materials of electric and optical cables.Part 41:Methods specific to polyethylene and polypropylene compounds.Resistance to environmental stress cracking.Measurement of the melt flow index.Carbon black and/o
  • GB/T 3048.10-2007 Test methods for electrical properties of electric cables and wires.Part 10: Spark test of extruded protective sheaths
  • GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires.Part 12: Partial discharge test
  • GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires.Part 13: Impulse voltage test
  • GB/T 3956-2008 Conductors of insulated cables
  • GB/T 6995.3-2008 Markings for electric wires and cables.Part 3:Identifications of cables and wires

GB/T 12706.2-2008 history

  • 2020 GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
  • 2008 GB/T 12706.1-2008 Rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cables and accessories Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um=3.6kV) cables
  • 2002 GB/T 12706.1-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV)up to 35kV(Um=40.5kV) Part 1: Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV)
  • 1991 GB 12706.2-1991 Copper or aluminium conductor extruded plastic insulated power cables with rated voltages up to 35kV--Part 2: Polyvinyl chloride insulated power cables
Power cables with extruded insulation and their accessories for rated voltages from 1kV(U<down m>=1.2kV>up to 35kV(U<down m>=40.5kV).Part 2:Cables for rated voltages from 6kV(U<down m>=7.2KV)up to 30kV(U<down m>=36kV)

GB/T 12706.2-2008 -All Parts




Copyright ©2024 All Rights Reserved