ASTM D6581-00(2005)
Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography

Standard No.
ASTM D6581-00(2005)
Release Date
2000
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D6581-08
Latest
ASTM D6581-18
Scope

The oxyhalides chlorite, chlorate, and bromate are inorganic disinfection by-products (DBPs) of considerable health risk concern worldwide. The occurrence of chlorite and chlorate is associated with the use of chlorine dioxide, as well as hypochlorite solutions used for drinking water disinfection. The occurrence of bromate is associated with the use of ozone for disinfection, wherein naturally occurring bromide is oxidized to bromate. Bromide is a naturally occurring precursor to the formation of bromate.

1.1 This test method covers the determination of the oxyhalides - chlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (non-carbonated) water by chemically suppressed ion chromatography. The ranges tested using this method for each analyte were as follows:

Chlorite20 to 500 g/L
Bromate5 to 30 g/L
Bromide20 to 200 g/L
Chlorate20 to 500 g/L

The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using this method. However, analysis of these ions is not the object of this test method.

1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 This test method is technically equivalent with Part B of U.S. EPA Method 300.1, titled "The Determination of Inorganic Anions in Drinking Water by Ion Chromatography".

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D6581-00(2005) Referenced Document

  • ASTM D1129 Standard Terminology Relating to Water
  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D2777 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
  • ASTM D3370 Standard Practices for Sampling Water from Closed Conduits
  • ASTM D3856 Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water
  • ASTM D5810 Standard Guide for Spiking into Aqueous Samples 
  • ASTM D5847 Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis

ASTM D6581-00(2005) history

  • 2018 ASTM D6581-18 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2012 ASTM D6581-12 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2008 ASTM D6581-08 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2000 ASTM D6581-00(2005) Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography
  • 2000 ASTM D6581-00 Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography
Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography



Copyright ©2024 All Rights Reserved