ASTM D6581-18
Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography

Standard No.
ASTM D6581-18
Release Date
2018
Published By
American Society for Testing and Materials (ASTM)
Latest
ASTM D6581-18
Scope
1.1 These multi-test methods cover the determination of the oxyhalides—chlorite, bromate, and chlorate, and bromide, in raw water, finished drinking water and bottled (noncarbonated) water by chemically and electrolytically suppressed ion chromatography. The ranges tested using these test methods for each analyte were as follows: Range Sections Test Method A: Chemically Suppressed Ion Chromatography 8 to 20 Chlorite 5 to 500 µg/L Bromate 1 to 25 µg/L Bromide 5 to 250 µg/L Chlorate 5 to 500 µg/L Test Method B: Electrolytically Suppressed Ion Chromatography 21 to 31 Chlorite 20 to 1000 µg/L Bromate 1 to 30 µg/L Bromide 20 to 200 µg/L Chlorate 20 to 1000 µg/L 1.1.1 The upper limits may be extended by appropriate sample dilution or by the use of a smaller injection volume. Other ions of interest, such as fluoride, chloride, nitrite, nitrate, phosphate, and sulfate may also be determined using these test methods. However, analysis of these ions is not the object of these test methods. 1.2 It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices. 1.3 These test methods are technically equivalent with Part B of U.S. EPA Method 300.1,2 titled “The Determination of Inorganic Anions in Drinking Water by Ion Chromatography.” 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D6581-18 Referenced Document

  • ASTM D1129 Standard Terminology Relating to Water
  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D2777 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
  • ASTM D3370 Standard Practices for Sampling Water from Closed Conduits
  • ASTM D3856 Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water
  • ASTM D5810 Standard Guide for Spiking into Aqueous Samples *2021-07-01 Update
  • ASTM D5847 Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis

ASTM D6581-18 history

  • 2018 ASTM D6581-18 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2012 ASTM D6581-12 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2008 ASTM D6581-08 Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography
  • 2000 ASTM D6581-00(2005) Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography
  • 2000 ASTM D6581-00 Standard Test Method for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Chemically Suppressed Ion Chromatography
Standard Test Methods for Bromate, Bromide, Chlorate, and Chlorite in Drinking Water by Suppressed Ion Chromatography



Copyright ©2024 All Rights Reserved