GB/T 36084-2018 Nanotechnology—Determination of copper, manganese and chromium ions in aqueous solution—Ultraviolet-visible spectrophotometry (English Version)
This standard specifies the determination of divalent copper ions (Cu2+), divalent manganese ions (Mn2+) and hexavalent chromium ions [Cr(VI )] content method. This standard is applicable to the determination of divalent copper ions, divalent manganese ions and hexavalent chromium ions in aqueous solution samples. After proper treatment of soil, food or biological samples, etc., they can be determined with reference to this standard. The detection limit of each ion in the water sample to be tested applicable to this standard is: the content of Cu2+ is not less than 1.00×10-7 mol? L-1, MnThe content of 2+ is not less than 1.00×10-6 mol? L-1, and the content of Cr(VI) is not less than 4.00×10-7 mol? L- 1. The pH range of water samples to be tested for this standard is: the pH range of the aqueous solution containing Cu2+ is 2~6, the pH range of the aqueous solution containing Mn2+ is 3~7, and the pH range of the aqueous solution containing Cr( The pH range of the aqueous solution of VI) is 1~6.