1.1 This standard specifies the type and basic parameters of the YLJ single-stage cantilever double-acting liquid ring chlorine pump. 1.2 This standard is applicable to liquid ring pumps for transporting chlorine gas with a purity of not less than 90%, a water content of not higher than 0.6%, and a pump temperature not higher than 40°C. The circulating fluid is 98% concentrated sulfuric acid with a pump temperature not higher than 30°C.
HG 2263-1992 history
2006HG/T 2262-2006 Single stage double action cantilever liquid-ring pump for chlorine gas
1992HG 2263-1992 Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters
HG 2263-1992 Single-stage cantilever double-acting liquid ring chlorine pump type and basic parameters was changed to HG/T 2262-2006 Single stage double action cantilever liquid-ring pump for chlorine gas.