This standard specifies a gas phase multi-method for the determination of pyridine in ambient gases and exhaust gases. This standard is applicable to the determination of pyridine in ambient air, air at unorganized emission monitoring points and organized emissions from stationary pollution sources. When collecting ambient air and unorganized emission monitoring point air, the sampling volume is L, and the fixed volume of the absorption liquid is 10 ml, the detection limit of the method is 0.02 mgmm, and the lower limit of determination is -0.08 mgm3s. When collecting organized emissions from fixed pollution sources For waste gas, the sampling volume is 30L, and when the fixed volume of the absorption liquid is S0 ml, the output limit of the method is 009mam, and the lower limit is 0.36 mg/m.
HJ 1219-2021 Referenced Document
GB/T 16157 "Determination of Particulate Matter in Exhaust from Stationary Pollution Sources and Sampling Methods of Gaseous Pollutants" Amendment No. 1
HJ 194 Technical specification for manual monitoring of ambient air quality "Revision No. 1"
HJ/T 55 Technical guidelines for fugitive emission monitoring of air pollutants
HJ 1219-2021 history
2021HJ 1219-2021 Determination of pyridine in ambient air and exhaust gas by gas chromatography