This International Standard specifies a method to determine if a flammable material such as a paint, varnish, paint binder, solvent, petroleum or a related product, when maintained at a selected equilibrium temperature and under the conditions of the test, gives off sufficient flammable vapour at this temperature to cause ignition on application of an external source of flame applied in a standard manner.
The method is suitable for use over the temperature range 5 to 65 °C, although some of the apparatus listed in annex A cannot
cover all of this range using the thermometer supplied with the apparatus. The procedure also makes allowance for deviations from standard atmospheric pressure.
DS/ISO 1516:1984 history
2002DS/EN ISO 1516:2002 Determination of flash/no flash - Closed cup equilibrium method
1984DS/ISO 1516:1984 Paints, varnishes, petroleum and related products. Flash/no-flash test (closed cup equilibrium method)
DS/ISO 1516:1984 Paints, varnishes, petroleum and related products. Flash/no-flash test (closed cup equilibrium method) was changed to DS/EN ISO 1516:2002 Determination of flash/no flash - Closed cup equilibrium method.