EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard. This European Standard deals with: a) loadbearing elements without a fire separating function:- walls; - floors; - roofs; - beams; - columns; - balconies; - walkways; - stairs. b) loadbearing elements with a fire separating function, with or without glazing, services and fixtures; - walls; - floors; - roofs; - raised floors. c) products and systems for protecting elements or parts of the works; - ceilings with no independent fire resistance; - fire protective coatings, claddings and screens; d) non-loadbearing elements or parts of works, with or without glazing, services and fixtures; - partitions; - facades (curtain walls) and external walls; - ceilings with independent fire resistance; - raised floors; - fire doors and shutters and their closing devices; - smoke control doors; - conveyor systems and their closures; - penetration seals; - linear joint seals; - service ducts and shafts; - chimneys. e) wall and ceiling coverings with fire protection ability. f) lift landing doors which are tested according to EN 81-58 are excluded from this European Standard. Lift landing doors which are tested in accordance with EN 1634-1, are classified in accordance with 7.5.5. Relevant test methods which have been prepared for these elements are listed in Clauses 2 and 7.
EN 13501-2:2016 Referenced Document
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures
EN 1364-1:2015 Fire resistance tests for non-loadbearing elements - Part 1: Walls
EN 1364-2:1999 Fire Resistance Tests for Non-Loadbearing Elements - Part 2: Ceilings
EN 1364-3:2014 Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly)
EN 1364-4:2014 Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
EN 1365-1:2012 Fire resistance tests for loadbearing elements - Part 1: Walls*, 2024-04-20 Update
EN 1365-2:2014 Fire resistance tests for loadbearing elements - Part 2: Floors and roofs
EN 1365-3:1999 Fire resistance tests for loadbearing elements - Part 3: Beams
EN 1365-4:1999 Fire resistance tests for loadbearing elements - Part 4: Columns
EN 1365-5:2004 Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways*, 2024-04-20 Update
EN 1365-6:2004 Fire resistance tests for loadbearing elements - Part 6: Stairs*, 2024-04-20 Update
EN 1366-5:2010 Fire resistance tests for service installations - Part 5: Service ducts and shafts
EN 81-58:2003 Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test
EN 13501-2:2016 history
2023EN 13501-2:2023 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance and/or smoke control tests, excluding ventilation services
2016EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
2007EN 13501-2:2007 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services (Incorporates Amendment A1: 2009)
2003EN 13501-2:2003 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services