ASTM C1831/C1831M-17
Standard Guide for Gamma Radiation Shielding Performance Testing

Standard No.
ASTM C1831/C1831M-17
Release Date
2017
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM C1831/C1831M-17(2022)
Latest
ASTM C1831/C1831M-17(2022)
Scope

5.1 Shielding performance testing should be performed to verify analytical predictions of shielding effectiveness, compliance with design requirements, and determine the location(s) of shielding deficiencies that may require either supplemental shielding, design modification, or changes to operating methods and procedures to resolve.

5.2 Dose rates higher than adjacent shielding may be expected in the vicinity of master-slave manipulator penetrations as a result of cable or tape clearance requirements within the mechanisms where they pass through the shield walls. This is true even with supplemental shielding installed in the manipulator through tube.

5.3 Similar to manipulator penetrations, when sources are placed directly in front of penetrations and gaps resulting from access doors or panels, radiation levels directly on the other side of the gaps or penetrations may be higher than levels in adjacent shielding or analytical predictions. If these test configurations are representative of how the shielded enclosure will actually be operated (that is, the test configuration is representative of engineered source and normally occupied work locations) than the additional expense of designing or modifying the shielded enclosure should be considered if that location is normally occupied and will result in a significant increase of dose rates to personnel.

5.4 Frames around shield windows may have a higher potential for shielding deficiencies.

5.5 Shield walls constructed of concrete may be subject to the formation of void spaces that could result in diminished shielding performance.

5.6 Background radiation levels in the area where the dose measurement data are being gathered shall be monitored and their contribution to measured dose rates accounted for in the data analysis as part of the test report.

1.1 This guide identifies appropriate test methods for determining the sufficiency of radiological shielding for hot cells and shielded enclosures.

1.2 After constructing or modifying radiological shielding, it is necessary to verify that shielding performance meets or exceeds the shielding performance requirements. This is typically accomplished using sealed test sources of much less activity than the design basis. This allows for modifications or correction of any discrepancies identified before the commissioning of the hot cell.

1.3 The guidance and practices recommended by this guide are applicable to both new and existing shielded facilities and enclosures for evaluating shielding suitability and locating the existence of shine paths or other shielding anomalies that result from design, manufacture, or construction.

1.4 Two types of testing may be performed.

1.4.1 Shielding performance verification testing provides evidence that the shielding configuration is sufficient for meeting established performance criteria and for identifying......

ASTM C1831/C1831M-17 Referenced Document

  • ASTM C859 Standard Terminology Relating to Nuclear Materials

ASTM C1831/C1831M-17 history

Standard Guide for Gamma Radiation Shielding Performance Testing