ASTM C1730-17
Standard Test Method for Particle Size Distribution of Advanced Ceramics by X-Ray Monitoring of Gravity Sedimentation

Standard No.
ASTM C1730-17
Release Date
2017
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM C1730-17(2022)
Latest
ASTM C1730-17(2022)
Scope

5.1 This test method is useful to both suppliers and users of powders, as outlined in 1.1 and 1.2, in determining particle size distribution for product specifications, manufacturing control, development, and research.

5.2 Users should be aware that sample concentrations used in this test method may not be what are considered ideal by some authorities, and that the range of this test method extends into the region where Brownian movement could be a factor in conventional sedimentation. Within the range of this test method, neither the sample concentration nor Brownian movement is believed to be significant. Standard reference materials traceable to national standards, of chemical composition specifically covered by this test method, are available from NIST,3 and perhaps other suppliers.

5.3 Reported particle size measurement is a function of the actual particle dimension and shape factor as well as the particular physical or chemical properties being measured. Caution is required when comparing data from instruments operating on different physical or chemical parameters or with different particle size measurement ranges. Sample acquisition, handling, and preparation can also affect reported particle size results.

5.4 Suppliers and users of data obtained using this test method need to agree upon the suitability of these data to provide specification for and allow performance prediction of the materials analyzed.

1.1 This test method covers the determination of particle size distribution of advanced ceramic powders. Experience has shown that this test method is satisfactory for the analysis of silicon carbide, silicon nitride, and zirconium oxide in the size range of 0.1 up to 50 µm.

1.1.1 However, the relationship between size and sedimentation velocity used in this test method assumes that particles sediment within the laminar flow regime. It is generally accepted that particles sedimenting with a Reynolds number of 0.3 or less will do so under conditions of laminar flow with negligible error. Particle size distribution analysis for particles settling with a larger Reynolds number may be incorrect due to turbulent flow. Some materials covered by this test method may settle in water with a Reynolds number greater than 0.3 if large particles are present. The user of this test method should calculate the Reynolds number of the largest particle expected to be present in order to judge the quality of obtained results. Reynolds number (Re) can be calculated using the following equation:

Equation C1730-17_1

ASTM C1730-17 Referenced Document

  • ASTM C1145 Standard Terminology of Advanced Ceramics
  • ASTM E1617 Standard Practice for Reporting Particle Size Characterization Data

ASTM C1730-17 history

  • 2022 ASTM C1730-17(2022) Standard Test Method for Particle Size Distribution of Advanced Ceramics by X-Ray Monitoring of Gravity Sedimentation
  • 2017 ASTM C1730-17 Standard Test Method for Particle Size Distribution of Advanced Ceramics by X-Ray Monitoring of Gravity Sedimentation
Standard Test Method for Particle Size Distribution of Advanced Ceramics by X-Ray Monitoring  of Gravity Sedimentation



Copyright ©2024 All Rights Reserved

where:

D   =   the diameter of the largest particle expected to be present, in cm,
ρ   =