EN 14791:2017
Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method

Standard No.
EN 14791:2017
Release Date
2017
Published By
European Committee for Standardization (CEN)
Latest
EN 14791:2017
Replace
FprEN 14791-2016
Scope
This European Standard specifies the standard reference method (SRM) for the determination of the sulphuric oxide SO2 in flue gases emitted to the atmosphere from ducts and stacks. It is based on a sampling system and two analytical principles: ion chromatography and the Thorin method. This European Standard specifies the performance characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on the measurement method. It applies to periodic monitoring and to the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN 14793:2017. This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the range of 0,5 mg/m3 to 2000 mg/m3 of SO2 for an ion-chromatography variant and 5 mg/m3 to 2000 mg/m3 of SO2 for the Thorin method according to emission limit values laid down in the Directive 2010/75/EU. NOTE 1 Emission limit values for SO2 laid down in the Directive 2010/75/EU are in the range of 30 mg/m3 to 800 mg/m3. The emission limit values of EU Directives are expressed in units of mg/m3 of SO2 on dry basis and at standard conditions of 273 K and 101,3 kPa. NOTE 2 The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex A.

EN 14791:2017 Referenced Document

  • EN 14793:2017 Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method
  • EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report*2024-04-20 Update
  • EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty ISO 14956: 2002
  • ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results - Part 6: Use in practice of accuracy values
  • ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
  • ISO/IEC Guide 99:2007 International vocabulary of metrology - Basic and general concepts and associated terms (VIM)

EN 14791:2017 history

  • 2017 EN 14791:2017 Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
  • 2005 EN 14791:2005 Stationary source emissions - Determination of mass concentration of sulphur dioxide - Reference method



Copyright ©2024 All Rights Reserved