ASTM D4821-16
Standard Guide for Carbon Black&x2014;Validation of Test Method Precision and Bias

Standard No.
ASTM D4821-16
Release Date
2016
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D4821-19
Latest
ASTM D4821-20
Scope

4.1 This guide provides insight into the environmental conditions required for operation of laboratories or to aid in the design of new laboratories that perform carbon black testing activities using those test methods that are under D24’s jurisdiction. This guide does not supersede any specific requirements a laboratory may choose to establish.

4.2 This guide recommends the use of statistical x-charts to graphically monitor test data determined for the ASTM reference blacks for those test methods given in Section 2. All laboratories are encouraged to utilize statistical x-charts and ASTM reference blacks because this enables a comparison of testing precision within and between laboratories. The guide describes practices for the use of repeatability and reproducibility limits and x-charts.

4.3 In addition to the calibration of a test method by physicochemical means, a statistical method for achieving calibration of a test method is presented (that is, normalization).

4.4 Poor test precision can be the result of poor repeatability or poor reproducibility or both. Causes may include inadequate operator training, improperly maintained equipment or laboratory environment, variation in sample preparation or analysis techniques, the lack of calibration or standardization of instrumentation, worn-out apparatus, reagents that do not meet specifications, different sources of instrumentation or equipment, and material heterogeneity. The sum of all sources of testing error is unique for an individual laboratory.

4.5 Precision data for ASTM Reference Blacks are found in Tables 1-3. These include standard reference blacks (SRB’s) Series 8, HT and INR Iodine Standards. The HT or INR Iodine standards are recommended for monitoring iodine testing.

(A) The iodine adsorption number of carbon black has been shown to decrease in value as the carbon black ages. Generally, the higher the surface area the faster the rate of change. Therefore, the target or mean values given in Table 1A may not be obtained due to this aging effect. Iodine Number testing should be monitored using HT or INR iodine standards and their reference values found in Table 2 and Table 3. See Section 10 for additional information.

Note 1: Preferred precision values are bolded in Tables 1-3.

1.1 This guide covers procedures for using the ASTM Standard Reference Blacks2 (SRBs) and the HT and INR Iodine Number Standards to continuously monitor the precision o......

ASTM D4821-16 history

  • 2020 ASTM D4821-20 Standard Guide for Carbon Black—Validation of Test Method Precision and Bias
  • 2019 ASTM D4821-19 Standard Guide for Carbon Black—Validation of Test Method Precision and Bias
  • 2016 ASTM D4821-16 Standard Guide for Carbon Black&x2014;Validation of Test Method Precision and Bias
  • 2015 ASTM D4821-15 Standard Guide for Carbon Black—Validation of Test Method Precision and Bias
  • 2014 ASTM D4821-14 Standard Guide for Carbon Blackmdash;Validation of Test Method Precision and Bias
  • 2007 ASTM D4821-07e1 Standard Guide for Carbon BlackValidation of Test Method Precision and Bias
  • 2007 ASTM D4821-07 Standard Guide for Carbon Black-Validation of Test Method Precision and Bias
  • 2006 ASTM D4821-06 Standard Guide for Carbon Black-Validation of Test Method Precision and Bias
  • 2005 ASTM D4821-05 Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
  • 2004 ASTM D4821-04 Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
  • 2003 ASTM D4821-03a Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
  • 2003 ASTM D4821-03 Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
  • 2001 ASTM D4821-01a Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
  • 2001 ASTM D4821-01 Standard Guide for Carbon Black—Validation of Test Method Precision and Bias
  • 1999 ASTM D4821-99 Standard Guide for Carbon Black8212;Validation of Test Method Precision and Bias
Standard Guide for Carbon Black&x2014;Validation of Test Method Precision and  Bias



Copyright ©2024 All Rights Reserved