Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens

Standard No.
ASTM F2147-01(2016)
Release Date
2001
Published By
American Society for Testing and Materials (ASTM)
Latest
ASTM F2147-01(2016)
Scope

5.1 In selecting a material for human contact in medical applications, it is important to ensure that the material will not stimulate the immune system to produce an allergic reaction under relevant exposure conditions. Extractable chemicals produced by skin contact or during physiological exposures may cause allergic reactions. Therefore, this practice provides for evaluations of solid or semisolid dosage forms using material extracts or direct evaluation of the test article. The rationale for this animal model is based on the fact that the guinea pig has been shown to be an appropriate animal model for predicting human contact dermatitis. Its tractable nature, its availability from reputable suppliers, the historical database of information already acquired using this species, and the correlation of such results to data on known human allergens, all contribute to its widespread use for allergenicity studies (1-5).4

5.2 The need for sensitization procedures other than the maximization test (Practice F720) is based on: (1) the need for a route of exposure more similar to use conditions; (2) concern over the use of adjuvant because of its recruitment of cell types to the test site which are not typically involved in immunologic reactions, and because of the discomfort this causes in the animals; (3) absence of a proper FCA-irritant control group in the traditional maximization design; and (4) the frequency of false positives often encountered with the GPMT. Both of these tests are internationally accepted (1).

1.1 This practice is intended to determine the potential for a substance, or material extract, to elicit contact dermal allergenicity.

1.2 This practice is intended as an alternative to the Guinea Pig Maximization Test (GPMT), given the limitations on dosage form and tendency for false positives associated with the latter test. See Rationale and References.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F2147-01(2016) Referenced Document

  • ASTM F619 Standard Practice for Extraction of Medical Plastics
  • ASTM F720 Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test

ASTM F2147-01(2016) history

  • 2001 ASTM F2147-01(2016) Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens
  • 2010 ASTM F2147-01(2010) Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens
  • 2006 ASTM F2147-01(2006) Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens
  • 2001 ASTM F2147-01 Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact Allergens
Standard Practice for  Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact  Allergens



Copyright ©2024 All Rights Reserved