This European Standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed fire sprinkler systems in buildings and industrial plants, and particular requirements for sprinkler systems that are integral to measures for the protection of life. This European Standard covers only the types of sprinkler specified in EN 12259-1. The requirements and recommendations of this European Standard are also applicable to any addition, extension, repair or other modification to a sprinkler system. They are not applicable to water spray or deluge systems. It covers the classification of hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems, and identifies construction details of buildings which are the minimum necessary for satisfactory performance of sprinkler systems complying with this European Standard. This European Standard does not cover water supplies to systems other than sprinklers. Its requirements can be used as guidance for other fixed firefighting extinguishing systems, provided that any specific requirements for other firefighting extinguishing supplies are taken into account. This European Standard is intended for use by those concerned with purchasing, designing, installing, testing, inspecting, approving, operating and maintaining automatic sprinkler systems, in order that such equipment will function as intended throughout its life. This European Standard is intended only for fixed fire sprinkler systems in buildings and other premises on land. Although the general principles might well apply to other uses (e. g. maritime use). For these other uses additional considerations should be taken into account. The requirements are not valid for automatic sprinkler systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry. Sprinkler system design deviations might be allowed when such deviations have been shown to provide a level of protection at least equivalent to this European Standard, for example by means of full-scale fire testing where appropriate, and where the design criteria have been fully documented.
EN 12845:2015 Referenced Document
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
EN 54-2:1997 Fire detection and fire alarm systems - Part 2: Control and indicating equipment (Incorporates Amendment A1: 2006)
EN 54-3:2014 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
EN 54-4:1997 Fire detection and fire alarm systems Part 4: Power supply equipment Includes Amendment A1: December 2002; A2: August 2006
EN 54-5:2000 Fire Detection and Fire Alarm Systems - Part 5: Heat Detectors - Point Detectors*, 2024-04-20 Update
EN 54-7:2000 Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization (Incorporates Amendments A1: 2002 and A2: 2006)*, 2024-04-20 Update
EN 12845:2015 history
2019EN 12845:2015/PRA1:2019 Fixed firefighting systems - Automatic sprinkler systems - Design@ installation and maintenance
2016EN 12845:2015/AC:2016 Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance
2015EN 12845:2015 Fixed firefighting systems - Automatic sprinkler systems - Design@ installation and maintenance
2004EN 12845:2004 Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance (Incorporates Amendment A2: 2009)
2003EN 12845:2003 Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance