ASTM D5810-96(2015)
Standard Guide for Spiking into Aqueous Samples&x2009;

Standard No.
ASTM D5810-96(2015)
Release Date
1996
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D5810-96(2021)
Latest
ASTM D5810-96(2021)
Scope

5.1 Matrix spiking is commonly used to determine the bias under specific analytical conditions, or the applicability of a test method to a particular sample matrix in that context, by determining the extent to which the spiked analyte or component is recovered from the sample matrix under these conditions. Reactions or interactions of the analyte or component of interest with the sample matrix may cause a significant positive or negative effect on recovery and may render the chosen analytical, or monitoring, process ineffectual for that sample matrix.

5.2 Matrix spiking can also be used to monitor the performance of a laboratory, individual instrument, or analyst as part of a regular quality assurance program. Changes in spike recoveries or recovery limits from the same or similar matrices over time may indicate variations in the quality of analytical results.

5.3 Spiking can be used to compare the recoveries of like spikes from reagent water samples and natural matrix samples (measured with and without spike) to distinguish between (1) unusual interference and (2) inherent method recovery and instability effects. This guide does not attempt to deal with the statistical significance of differences in spike recoveries from different matrices.

5.4 Special precautions shall be observed when nonlaboratory personnel perform spiking in the field. It is recommended that all spike preparation work be performed in a laboratory by experienced analysts so that the field operation consists solely of adding a prepared spiking solution to the sample matrix. Training of field personnel and validation of their spiking techniques are necessary to ensure that spikes are added accurately and reproducibly. Duplicate field spikes can be used to document the reproducibility of the technique. When environmentally labile compounds are used as spikes, the spiking solution shall be protected up to the point of use by appropriate means such as chilling, protection from sunlight and oxygen, or chemical preservation.

Note 1: Any field spiked sample, if known to the laboratory, should be labeled as a field spike in the final results report. Also, whenever possible, field spiking of volatile compounds should be avoided.

5.5 It is often tacitly assumed that an analyte component is recovered from samples to approximately the same extent that a spike of the same analyte is recovered from a spiked sample. One reason that this assumption may be incorrect is that the spike may not be bound up in the sample (for example, with suspended matter) in the same way that the naturally occurring analyte is bound in the sample. The spike may therefore be recovered from the sample differently than the background level of the analyte. It is not good practice to correct analytical data using spike recoveries for this reason, as well as the fact that bias corrections can add variability. However, spike recovery information should be reported along with related sample analysis results.

5.6 This guide is also applicable to the use of spi......

ASTM D5810-96(2015) Referenced Document

  • ASTM D1129 Standard Terminology Relating to Water*1999-04-20 Update
  • ASTM D1193 Standard Specification for Reagent Water*1999-04-20 Update
  • ASTM D3694 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents*2017-12-15 Update
  • ASTM D3856 Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water
  • ASTM D4375 Standard Practice for Basic Statistics in Committee D-19 on Water
  • ASTM E200 Standard Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical Analysis*1997-04-20 Update