JB/T 9591.3-2015
Gas turbine.Cleanliness verifing for oil system.Measuring particulate contaminant in oil by microscopic counting method (English Version)

Standard No.
JB/T 9591.3-2015
Language
Chinese, Available in English version
Release Date
2015
Published By
Professional Standard - Machinery
Latest
JB/T 9591.3-2015
Replace
JB/T 9591.3-1999
Scope
This part of JB/T 9591 specifies a method for determining the cleanliness of gas turbine oil systems by using a microscope to count solid particles on the filter membrane surface in different size ranges to determine the number of solid particle contaminants in oil samples. It includes two methods: manual particle counting and image analysis counting. This section is suitable for determining the pollution degree of lubricating oil, hydraulic oil and fuel oil used in gas turbines; it is also suitable for measuring the pollution degree of oil used in other mechanical hydraulic systems.

JB/T 9591.3-2015 Referenced Document

  • GB/T 12804 Laboratory glassware.Graduated measuring cylinders
  • JB/T 9591.1 Gas turbine.Oil system cleanliness
  • JB/T 9591.2 Gas turbine.Cleanliness testing for oil system.Sampling method

JB/T 9591.3-2015 history

  • 2015 JB/T 9591.3-2015 Gas turbine.Cleanliness verifing for oil system.Measuring particulate contaminant in oil by microscopic counting method
  • 1999 JB/T 9591.3-1999 Cleanliness test for oil system of gas turbine measuring solid particle contaminant in oil liquid by microscopic counting method



Copyright ©2024 All Rights Reserved