Scope
This Technical Specification specifies a measurement method for the determination of the particle bound polycyclic aromatic hydrocarbon (PAH) compounds benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF), benzo[j]fluoranthene (BjF), benzo[k]fluoranthene (BkF), dibenz[a,h]anthracene (DBahA), indeno[1,2,3-cd]pyrene (INP) and benzo[ghi]perylene (BghiP) in ambient air, which can be used in the framework of Council Directive 2008/50/EC and Directive 2004/107/EC. This document specifies performance characteristics and performance criteria for this measurement method. The performance characteristics of the measurement method are based on a sampling period of 24 h. This Technical Specification describes a measurement method which comprises sampling of the selected PAH compounds as part of the PM10 particles, sample extraction and analysis by high performance liquid chromatography (HPLC) with fluorescence detector (FLD) or by gas chromatography with mass spectrometric detection (GC-MS). The method is applicable for the measurement of the PAH compounds in the concentration range from approx. 0,04 ng/m 3 to approximately 20 ng/m 3 for BaA, BbF, BjF, BkF, BaP, INP and BghiP and 0,02 ng/m 3 to approximately 2 ng/m 3 for DBahA. Table 1 shows examples for concentrations of the compounds (annual mean values) for sampling sites with different characteristics. The lower limit of the applicable range depends on the noise level of the detector and the variability of the laboratory filter blank.

PD CEN/TS 16645:2014 Referenced Document

  • EN 12341:1998 Air Quality - Determination of the PM10 Fraction of Suspended Particulate Matter - Reference Method and Field Test Procedure to Demonstrate Reference Equivalence of Measurement Methods
  • EN 13274-7:2008 Respiratory protective devices - Methods of test - Part 7: Determination of particle filter penetration
  • EN 14625:2012 Ambient air - Standard method for the measurement of the concentration of ozone by ultraviolet photometry
  • EN 14902:2005 Ambient air quality - Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter
  • EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
  • EN 15980:2011 Air quality - Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene
  • EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking*2024-04-20 Update
  • EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
  • EN ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005)
  • ISO 12884:2000 Ambient air - Determination of total (gas- and particle-phase) polycyclic aromatic hydrocarbons - Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses
  • ISO 16362:2005 Ambient air - Determination of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography
  • ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • ISO 7870-2:2013 Control charts - Part 2: Shewhart control charts
  • ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
  • VDI 2100 Blatt 4-2003 Gaseous ambient air measurement - Indoor air pollution measurement - Gas chromatographic determination of organic compounds; Calibration procedures as a measure for quality assurance