Scope
This Technical Specification specifies procedures for the sampling, preparation and analysis of individual volatile organic compounds (VOCs) in waste gas, such as those arising from solvent using processes. Sampling occurs by adsorption on sorbents, preparation by solvent extraction or thermodesorption and analysis by gas chromatography. Examples of individual VOC are given in relevant industry sector BAT Reference documents (BREFs). The results obtained are expressed as the mass concentration (mg/m 3 ) of the individual gaseous organic compounds. This document is suitable for measuring individual VOCs whose ranges vary depending on compound and test method, refer to Annex B and C. This Technical Specification may be used to meet the monitoring requirements of the Industrial Emission Directive (IED) and associated supporting documents. This Technical Specification is not suitable for measuring total organic carbon (TOC). For the measurement of the mass concentration of total organic carbon then EN 12619 is applicable.

PD CEN/TS 13649:2014 Referenced Document

  • ASTM D3686-13 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)
  • ASTM D3687-07 Standard Practice for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method*2024-04-20 Update
  • ASTM D6196-03 Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air*2024-04-20 Update
  • EN 1076:2009 Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods*2024-04-20 Update
  • EN 12619:2013 Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method [Superseded: CEN EN 13526]
  • EN 14662-1:2005 Ambient air quality - Standard method for measurement of benzene concentrations - Part 1: Pumped sampling followed by thermal desorption and gas chromatography
  • EN 14662-2:2005 Ambient air quality - Standard method for measurement of benzene concentrations - Part 2: Pumped sampling followed by solvent desorption and gas chromatography
  • EN 14662-3:2005 Ambient Air Quality - Standard method for the measurement of benzene concentrations - Part 3: Automated pumped sampling with in situ gas chromatography
  • EN 14662-4:2005 Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography
  • EN 14662-5:2005 Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography
  • EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report*2024-04-20 Update
  • EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty ISO 14956: 2002
  • EN ISO 16017-1:2000 Indoor, Ambient and Workplace Air - Sampling and Analysis of Volatile Organic Compounds by Sorbent Tube/Thermal Desorption/Capillary Gas Chromatography - Part 1: Pumped Sampling ISO 16017-1:2000*2024-04-20 Update
  • EN ISO 16017-2:2003 Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling
  • ISO 16000-6:2011 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
  • ISO 16200-1:2001 Workplace air quality - Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography - Part 1: Pumped sampling method
  • ISO 16200-2:2000 Workplace air quality - Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography - Part 2: Diffusive sampling method
  • ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

PD CEN/TS 13649:2014 history

  • 2014 PD CEN/TS 13649:2014 Stationary source emissions - Determination of the mass concentration of individual gaseous organic compounds - Sorptive sampling method followed by solvent extraction or thermal desorption
Stationary source emissions - Determination of the mass concentration of individual gaseous organic compounds - Sorptive sampling method followed by solvent extraction or thermal desorption