General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 30908-2014
Scope
This standard specifies two methods for the determination of boron in photographic processing waste liquid. Method A is the mannitol boric acid complex method, using the titration method of mannitol boric acid complex (an acid stronger than boric acid) to determine borate, and the scope of application is that the boron content is higher than 0.1 mg/L. In the range of 0.1 mg/L~5 mg/L, phosphate was removed by precipitation with lead acetate. In the range of 1 mg/L~100 mg/L, the sample was diluted 25 times, and if the concentration of phosphorus was lower than 500 mg/L, the interference of phosphorus could be removed. Method B is methylene blue spectrophotometry, suitable for boron concentrations ranging from 0.1 mg/L to 1.0 mg/L. This standard applies to the analysis of boron in waste liquid discharged from photographic processing.