ASTM C1214-13
Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method

Standard No.
ASTM C1214-13
Release Date
2013
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM C1214-19
Latest
ASTM C1214-19
Scope

5.1 This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing.

1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 4 to 36-in. diameter circular concrete pipe sewerlines utilizing gasketed joints.

Note 1The user of this test method is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in Table 1 are for pipelines. Holding times for testing an individual pipe may have to be increased to allow for the accumulation of leakage when the tested pipe are incorporated into a continuous pipeline.
TABLE 1 Minimum Test Time

ASTM C1214-13 Referenced Document

  • ASTM C822 Standard Terminology Relating to Concrete Pipe and Related Products
  • ASTM C924 Standard Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method
  • ASTM C969 Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines

ASTM C1214-13 history

  • 2019 ASTM C1214-19 Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
  • 2013 ASTM C1214-13 Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
  • 2002 ASTM C1214-02(2009) Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
  • 2002 ASTM C1214-02 Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
  • 1994 ASTM C1214-94(2000) Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
Standard Test Method for  Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method



Copyright ©2024 All Rights Reserved

Nominal
Pipe
Size, in.

T (Time),
min/100 ft

Nominal
Pipe
Size, in.

T (Time),
min/100 ft

 4

0.3

21

3.0

 6

0.7

24

3.6

 8

1.2

27

4.2

10

1.5

30

4.8