Scope
This European Standard specifies general requirements for the construction, testing and performance of electrically operated carbon monoxide gas detection apparatus, designed for continuous operation in domestic premises. The apparatus may be mains or battery powered. Such apparatus is intended to warn of an accumulation of CO, enabling the occupant to react before being exposed to significant risk.Additional requirements for apparatus to be used in recreational vehicles and similar premises are specified in EN 50291-2.NOTE For caravan holiday homes EN 50291-1 applies.This European Standard specifies two types of apparatus, these are• type A – to provide a

DS/EN 50291-1:2010 history

  • 2021 DS/EN 50291-1:2021 Gas detectors – Electrical apparatus for the detection of carbon monoxide in domestic premises – Part 1: Test methods and performance requirements
  • 2012 DS/EN 50291-1/A1:2012 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements
  • 2010 DS/EN 50291-1:2010 Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements