ASTM E1300-12a
Standard Practice for Determining Load Resistance of Glass in Buildings

Standard No.
ASTM E1300-12a
Release Date
2012
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E1300-12ae1
Latest
ASTM E1300-24
Scope

This practice is used to determine the LR of specified glass types and constructions exposed to uniform lateral loads.

Use of this practice assumes:

The glass is free of edge damage and is properly glazed,

The glass has not been subjected to abuse,

The surface condition of the glass is typical of glass that has been in service for several years, and is weaker than freshly manufactured glass due to minor abrasions on exposed surfaces,

The glass edge support system is sufficiently stiff to limit the lateral deflections of the supported glass edges to no more than 1/175 of their lengths. The specified design load shall be used for this calculation.

The center of glass deflection will not result in loss of edge support.

Note 18212;This practice does not address aesthetic issues caused by glass deflection.

Many other factors shall be considered in glass type and thickness selection. These factors include but are not limited to: thermal stresses, spontaneous breakage of tempered glass, the effects of windborne debris, excessive deflections, behavior of glass fragments after breakage, seismic effects, heat flow, edge bite, noise abatement, potential post-breakage consequences, and so forth. In addition, considerations set forth in building codes along with criteria presented in safety glazing standards and site specific concerns may control the ultimate glass type and thickness selection.

For situations not specifically addressed in this standard, the design professional shall use engineering analysis and judgment to determine the LR of glass in buildings.

1.1 This practice describes procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.

1.2 This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of wind load, snow load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.

1.3 This practice applies only to monolithic and laminated glass constructions of rectangular shape with continuous lateral support along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; (2) glass supported on two sides acts as a simply supported beam; and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass units with four-sided edge support.

1.4 This practice does not apply to any form of wired, patterned, etched, sandblasted, drilled, notched, or grooved glass with surface and edge treatments that alter the glass strength.

1.5 This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and type of glass selected also depends upon a variety of other factors (see 5.3).

1.6 Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides.

1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for mathematical conversions to inch-pound units that are provide......

ASTM E1300-12a history

  • 2024 ASTM E1300-24 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2016 ASTM E1300-16 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12ae1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12a Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2012 ASTM E1300-12 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2009 ASTM E1300-09a Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2009 ASTM E1300-09 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2007 ASTM E1300-07e1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2004 ASTM E1300-04e1 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2004 ASTM E1300-04 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2003 ASTM E1300-03 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2002 ASTM E1300-02 Standard Practice for Determining Load Resistance of Glass in Buildings
  • 2000 ASTM E1300-00 Standard Practice for Determining Load Resistance of Glass in Buildings



Copyright ©2024 All Rights Reserved