1.2 This test method is limited to the determination of the zirconium content of a liquid zirconium drier that does not contain other drier elements. The test method is not applicable to drier blends and does not differentiate hafnium from zirconium.
1.3 All cations that can be titrated with EDTA in acid media interfere and must not be present in the sample.
1.4 This test method has been tested for concentrations of 6 and 128201;% zirconium, but there is no reason to believe that it is not suitable for higher or lower zirconium concentrations, provided specimen size is adjusted proportionately.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Copyright ©2024 All Rights Reserved