IEC 62271-107:2012
High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

Standard No.
IEC 62271-107:2012
Release Date
2012
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 62271-107:2019 RLV
Latest
IEC 62271-107:2019 RLV
Replace
IEC 17A/997/FDIS:2012 IEC 62271-107:2005
Scope
"This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: ?C breaking@ at the rated recovery voltage@ any load or fault current up to and including the rated short-circuit breaking current; ?C making@ at the rated voltage@ circuits to which the rated short-circuit breaking current applies. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance@ but exclude distribution lines or cables@ as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents@ up to the fused circuit-switcher rated take-over current@ are dealt with by supplementary devices (strikers@ relays@ etc.)@ properly arranged@ tripping the circuit-switcher. Fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher. NOTE 1 In this standard the term ""fuse"" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8. NOTE 2 Other circuit-switchers exist; see reference [1]1. Devices that require a dependent manual operation are not covered by this standard. Fuses are covered by IEC 60282-1. Earthing switches forming an integral part of a circuit-switcher are covered by IEC 62271-102. Installation in enclosure@ if any@ is covered either by IEC 62271-200 or by IEC 62271-201. 1 Numbers between brackets refer to the Bibliography."

IEC 62271-107:2012 history

  • 0000 IEC 62271-107:2019 RLV
  • 2012 IEC 62271-107:2012 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV
  • 2005 IEC 62271-107:2005 High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV